ABB Electrical Products

We are offering a vast array of ABB Electrical Products from the leading brand ABB. The Miniature Circuit Breakers (MCBs) that we procure from ABB are among the best available in the market. These are designed with proven, trusted, and reliable technology to provide enhanced operating safety. These are also available in different sizes.

ABB 3 Pole AF Contactors

Request Callback

₹ 19254 / Unit Get Latest Price

Contactor TypeAC Power Contactors
Number of Poles2 Pole
Voltage TypeDC
Voltage (V)220
Filter Tuned5th

Minimum order quantity: 1 Unit

We are the trader, wholesaler and exporter of ABB AF205-30-11TO AF2650-30-11 These Products are available in 3 Pole Contactors .

Specifications:

  • Product Net Width:44
  • Product Net Height:74 mm
  • Product Net Depth:74 mm
  • Product Net Weight:0.340 kg
  • Rated Operational Power AC-3 (Pe):(400 V)
  • Three Phase 2.2 kW
  • Rated Operational Voltage: Main Circuit 690 V AC
  • Rated Operational Current AC-3 (Ie):0.10 TO 32 A
  • Rated Frequency (f): Main Circuit 50 Hz
  • Main Circuit: 60 Hz.
Get Best Price Of ABB AF Contactors For Rs.19254/-

ABB MO 132 Motor Starter

Request Callback

₹ 2235 / Unit Get Latest Price

PhaseSingle Phase
BrandABB
Starter TypeFully Automatic
Coil Voltage24 V
Current Rating20 A

Minimum order quantity: 1 Unit

We are the trader, wholesaler and exporter of ABB MO 132-0.16 TO MO 132-32 These Produts are avilable in Motor Starter.

Specifications:
  • Product Net Width:45 mm
  • Product Net Height:90 mm
  • Product Net Depth:86.75 mm
  • Product Net Weight:0.215 kg
  • Rated Instantaneous Short-Circuit Current Setting (Ii):3.1 A
  • Setting Range: None
  • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 0.06 kW
  • Rated Operational Voltage: Main Circuit 690 V AC
  • Rated Operational Current (Ie):0.10 to 32 A

MS116-0.63 Manual Motor Starter

Request Callback

₹ 4900 / Piece Get Latest Price

PhaseThree Phase
BrandABB
Voltage690V
Current0.63A
Power0.63V
Starter Typemanual
Model Name/NumberMS116-0.63 Manual Motor Starter
Suitable ForThree and single phase Applications

The MS116-0.63 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.

ABB A50 -30-00

Request Callback

₹ 4506 / Unit Get Latest Price

Number of Poles3
Rated Voltage220-230v
Switching Current50Amps
PhaseThree Phase
Mounting TypeFront mounted

Minimum order quantity: 1 Unit

General Information
  • Extended Product Type:A50-30-00 220-230V 50Hz / 230-240V 60Hz
  • Product ID:1SBL351001R8000
  • Catalog Description:A50-30-00 220-230V 50Hz / 230-240V 60Hz Contactor
  • Long Description:A50 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC / 1000 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
Dimensions
  • Product Net Width:70 mm
  • Product Net Depth:108 mm
  • Product Net Height:110 mm
  • Product Net Weight:1.160 kg
Specification
  • Number of Main Contacts NO:3
  • Number of Main Contacts NC:0
  • Number of Auxiliary Contacts NO:0
  • Number of Auxiliary Contacts NC:0
  • Standards:Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Operational Voltage:Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A
  • Rated Operational Current AC-1 (Ie):(690 V) 40 °C 100 A
    (690 V) 55 °C 85 A
    (690 V) 70 °C 70 A
  • Rated Operational Current AC-3 (Ie):(1000 V) 55 °C 23 A
    (220 / 230 / 240 V) 55 °C 53 A
    (380 / 400 V) 55 °C 50 A
    (415 V) 55 °C 50 A
    (440 V) 55 °C 45 A
    (500 V) 55 °C 45 A
    (690 V) 55 °C 35 A
  • Rated Operational Power AC-3 (Pe):(220 / 230 / 240 V) 15 kW
    (380 / 400 V) 22 kW
    (415 V) 25 kW
    (440 V) 25 kW
    (500 V) 30 kW
    (690 V) 30 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
  • Short-Circuit Protective Devices:gG Type Fuses 100 A
  • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
  • Maximum Electrical Switching Frequency:AC-1 600 cycles per hour
    AC-2 / AC-4 150 cycles per hour
    AC-3 600 cycles per hour
  • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):8 kV
  • Maximum Mechanical Switching Frequency:3600 cycles per hour
  • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
  • Rated Control Circuit Voltage (Uc):50 Hz 220 … 230 V
    60 Hz 230 … 240 V
  • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • Terminal Type:Screw Terminals
Environmental
  • Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
    Close to Contactor for Storage -60 ... +80 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
  • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible:3000 m
  • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

    ABB A 12-30-01

    Request Callback

    ₹ 782 / Unit Get Latest Price

    Voltage220-230v
    Number of Poles3 Pole
    Current12Amps
    BrandABB
    Model NumberAF12-30-01

    Minimum order quantity: 1 Unit

    • General Information
    • Extended Product Type:A12-30-01 220-230V 50Hz / 230-240V 60Hz
    • Product ID:1SBL161001R8001
    • Catalog Description:A12-30-01 220-230V 50Hz / 230-240V 60Hz Contactor
    • Long Description:A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
    Dimensions
    • Product Net Width:44 mm
    • Product Net Depth:74 mm
    • Product Net Height:74 mm
    • Product Net Weight:0.340 kg
    Specification
    • Number of Main Contacts NO:3
    • Number of Main Contacts NC:0
    • Number of Auxiliary Contacts NO:0
    • Number of Auxiliary Contacts NC:1
    • Standards:Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
    • Rated Operational Voltage:Main Circuit 690 V
    • Rated Frequency (f):Supply Circuit 50 Hz
      Supply Circuit 60 Hz
    • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A
      acc. to IEC 60947-5-1, q = 40 °C 16 A
    • Rated Operational Current AC-1 (Ie):(690 V) 40 °C 27 A
      (690 V) 55 °C 25 A
      (690 V) 70 °C 20 A
    • Rated Operational Current AC-3 (Ie):(220 / 230 / 240 V) 55 °C 12 A
      (380 / 400 V) 55 °C 12 A
      (415 V) 55 °C 12 A
      (440 V) 55 °C 12 A
      (500 V) 55 °C 12 A
      (690 V) 55 °C 9 A
    • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
    • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
    • Rated Operational Current AC-15 (Ie):(220 / 240 V) 4 A
      (24 / 127 V) 6 A
      (380 / 440 V) 3 A
      (500 V) 2 A
      (690 V) 2 A
    • Short-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 A
      gG Type Fuses 32 A
    • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
    • Maximum Electrical Switching Frequency:AC-1 600 cycles per hour
      AC-2 / AC-4 300 cycles per hour
      AC-3 1200 cycles per hour
    • Rated Operational Current DC-13 (Ie):(125 V) 1.1 / 138 A
      (24 V) 6 / 144 A
      (250 V) 0.55 / 138 A
      (48 V) 2.8 / 134 A
      (72 V) 2 / 144 A
    • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
      acc. to UL/CSA 600 V
    • Rated Impulse Withstand Voltage (Uimp):8 kV
    • Mechanical Durability:10 million
    • Maximum Mechanical Switching Frequency:3600 cycles per hour
    • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
    • Rated Control Circuit Voltage (Uc):50 Hz 220 … 230 V
      60 Hz 230 … 240 V
    • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    • Connecting terminals (delivered in open position) Main poles:M 3.5 (+,-) pozidriv 2 screws with cable clamp
    • Terminal Type:Screw Terminals
    Environmental
    • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
    • Maximum Operating Altitude Permissible:3000 m
    • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

      AF146-30 -11 12

      Request Callback

      ₹ 22630.04 / Piece Get Latest Price

      Usage/ApplicationIndustrial
      I Deal InNew Only
      Country of OriginMade in India
      Rated Operational Voltage:Main Circuit 1000 V
      Rated Frequency (f):Main Circuit 50 / 60 Hz
      Terminal Type:Double Clamp

      Minimum order quantity: 1 Piece

      Long Description:
      The AF146-30-11-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use.


      Product ID:1SFL467001R1211

      Abb A40 30 10

      Request Callback

      ₹ 3978 / Unit Get Latest Price

      Contactor TypeDC Power Contactors
      Number of Poles3
      Filter Tuned5th
      PhaseThree Phase
      Rated Voltage220-230V

      Minimum order quantity: 1 Unit

      General Information
      • Extended Product Type:A40-30-10 220-230V 50Hz / 230-240V 60Hz
      • Product ID:1SBL321001R8010
      • Catalog Description:A40-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
      • Long Description:A40 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
      Dimensions
      • Product Net Width:54 mm
      • Product Net Depth:108.3 mm
      • Product Net Height:90 mm
      • Product Net Weight:0.710 kg
      Specification
      • Number of Main Contacts NO:3
      • Number of Main Contacts NC:0
      • Number of Auxiliary Contacts NO:1
      • Number of Auxiliary Contacts NC:0
      • Standards:Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
      • Rated Operational Voltage:Main Circuit 690 V
      • Rated Frequency (f):Supply Circuit 50 Hz
        Supply Circuit 60 Hz
      • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A
        acc. to IEC 60947-5-1, q = 40 °C 16 A
      • Rated Operational Current AC-1 (Ie):(690 V) 40 °C 60 A
        (690 V) 55 °C 60 A
        (690 V) 70 °C 42 A
      • Rated Operational Current AC-3 (Ie):(220 / 230 / 240 V) 55 °C 40 A
        (380 / 400 V) 55 °C 37 A
        (415 V) 55 °C 37 A
        (440 V) 55 °C 37 A
        (500 V) 55 °C 33 A
        (690 V) 55 °C 25 A
      • Rated Operational Power AC-3 (Pe):(220 / 230 / 240 V) 11 kW
        (380 / 400 V) 18.5 kW
        (415 V) 18.5 kW
        (440 V) 22 kW
        (500 V) 22 kW
        (690 V) 22 kW
      • Short-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 A
        gG Type Fuses 63 A
      • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
        cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
      • Maximum Electrical Switching Frequency:AC-1 600 cycles per hour
        AC-2 / AC-4 300 cycles per hour
        AC-3 1200 cycles per hour
      • Rated Operational Current DC-13 (Ie):(125 V) 1.1 / 138 A
        (24 V) 6 / 144 A
        (250 V) 0.55 / 138 A
        (48 V) 2.8 / 134 A
        (72 V) 2 / 144 A
      • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
        acc. to UL/CSA 600 V
      • Rated Impulse Withstand Voltage (Uimp):8 kV
      • Maximum Mechanical Switching Frequency:3600 cycles per hour
      • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
      • Rated Control Circuit Voltage (Uc):50 Hz 220 … 230 V
        60 Hz 230 … 240 V
      • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
      • Connecting terminals (delivered in open position) Main poles:M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector
      • Terminal Type:Screw Terminals
      Environmental
      • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
      • Maximum Operating Altitude Permissible:3000 m

          ABB MS 132 Motor Starter

          Request Callback

          ₹ 2343 / Unit Get Latest Price

          Voltage220 V
          PhaseThree Phase
          BrandABB
          Coil Voltage480 V
          Starter TypeFully Automatic

          Minimum order quantity: 1 Unit

          We are the trader, wholesaler and exporter of ABB MS 132-0.16 to MS 132-32 These Products are available in Motor Starter.

          Specifications:
          • Product Net Width:45 mm
          • Product Net Height:90 mm
          • Product Net Depth:86.75 mm
          • Product Net Weight:0.215 kg
          • Rated Instantaneous Short-Circuit Current Setting (Ii):2 A
          • Setting Range:0.1 ... 32A
          • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 0.03 kW
          • Rated Operational Voltage: Main Circuit 690 V AC
          • Main Circuit 250 V DC
          • Rated Operational Current (Ie):0.10 to 32 A

          MS116-6.3

          Request Callback

          ₹ 4960 / Piece Get Latest Price

          Number of Poles:3
          Rated Operational Voltage:Main Circuit 690 V AC
          Rated Operational Current6.3 A
          Rated Frequency (f):Main Circuit 50 Hz Main Circuit 60 Hz
          Rated Insulation Voltage690 V
          Actuator Type:Rotary Handle
          Contact Position Indication:ON / OFF

          Minimum order quantity: 1 Piece

          Product ID:1SAM250000R1009

          Catalog Description:MS116-6.3 Manual Motor Starter 4.0 ... 6.3 A

          ABB CA4-40E Contactors

          Request Callback

          ₹ 539 / Unit Get Latest Price

          Number of Poles4
          Mounting TypeFront mounted
          PhaseThree Phase
          Rated Voltage220-230V

          Minimum order quantity: 1 Unit

          General Information

          Extended Product Type:CA4-40EProduct ID:1SBN010140R1040Catalog Description:CA4-40E Auxiliary Contact BlockLong Description:CA4-40E Auxiliary Contact Block
          Dimensions
          Product Net Weight:0.055 kg
          Specification

          Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
          Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
          Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
          Rigid 1/2x 1...2.5 mm²Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-5-1, q = 40 °C 16 AIIT Publishing Status:Level 0 - Information enabledMaximum Electrical Switching Frequency:AC-15 1200 cycles per hour
          DC-13 900 cycles per hourMaximum Mechanical Switching Frequency:3600 cycles per hourMounted Auxiliary Contacts:4 NO, 0 NCNumber of Auxiliary Contacts NC:0Number of Auxiliary Contacts NO:4Order Multiple:1 pieceProduct Main Type:Accessories for Block ContactorsProduct Name:Auxiliary Contact BlockRated Frequency (f):Auxiliary Circuit 50 / 60 HzRated Impulse Withstand Voltage (Uimp):6 kVRated Insulation Voltage (Ui):acc. to UL/CSA 600 V
          acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 VRated Operational Current AC-15 (Ie):(220 / 240 V) 4 A
          (24 / 127 V) 6 A
          (400 / 440 V) 3 A
          (500 V) 2 A
          (690 V) 2 ARated Operational Current DC-13 (Ie):(110 V) 0.55 A / 60 W
          (125 V) 0.55 A / 69 W
          (220 V) 0.27 A / 60 W
          (24 V) 6 A / 144 W
          (250 V) 0.27 A / 68 W
          (400 V) 0.15 A / 60 W
          (48 V) 2.8 A / 134 W
          (500 V) 0.13 A / 65 W
          (600 V) 0.1 A / 60 W
          (72 V) 1 A / 72 WRated Operational Voltage:Auxiliary Circuit 24 ... 690 VRated Short-time Withstand Current (Icw):for 0.1 s 140 A
          for 1 s 100 ARoHS Date:20090609Suitable For:AF09
          AF16
          AF26
          AF30
          AF38
          AF40
          AF52
          AF65
          AF80
          AF96Terminal Type:Screw TerminalsTightening Torque:Auxiliary Circuit 1.2 N·mWire Stripping Length:Auxiliary Circuit 10 mm

          ABB UA-95-30-00RA Contactor

          Request Callback

          Get Latest Price

          Contactor TypeAC Power Contactors
          Number of Poles2 Pole
          Voltage TypeAC
          Voltage (V)220
          Electricity TypeAC
          Usage/ApplicationCommercial
          General Information
          • Extended Product Type:UA95-30-00RA 220-230V 50Hz
          • Product ID:1SFL431024R8000
          • Catalog Description:UA95-30-00RA 220-230V 50Hz Contactor
          • Long Description:A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 100 times the nominal RMS current. Operated with a control voltage, versions from 24…….690 V
          Dimensions
          • Product Net Width:90.0 mm
          • Product Net Depth:155.6 mm
          • Product Net Height:170.0 mm
          • Product Net Weight:2.000 kg
          Specification
            • Number of Main Contacts NO:3
            • Number of Main Contacts NC:0
            • Number of Auxiliary Contacts NO:0
            • Number of Auxiliary Contacts NC:0
            • Rated Operational Voltage:Main Circuit 1000 V
            • Rated Frequency (f):Main Circuit 50 Hz
            • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
            • Rated Operational Current AC-1 (Ie):(690 V) 55 °C 135 A
              (690 V) 40 °C 145 A
              (690 V) 70 °C 115 A
            • Rated Operational Current AC-3 (Ie):(1000 V) 55 °C 30 A
              (690 V) 55 °C 65 A
              (415 V) 55 °C 96 A
              (220 / 230 / 240 V) 55 °C 96 A
              (440 V) 55 °C 93 A
              (380 / 400 V) 55 °C 96 A
              (500 V) 55 °C 80 A
            • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
            • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
            • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
              cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
            • Maximum Electrical Switching Frequency:AC-3 300 cycles per hour
              AC-1 300 cycles per hour
              AC-2 / AC-4 150 cycles per hour
            • Rated Insulation Voltage (Ui):acc. to UL/CSA 600 V
              acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
            • Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
            • Mechanical Durability:10 million
            • Maximum Mechanical Switching Frequency:3600 cycles per hour
            • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
            • Rated Control Circuit Voltage (Uc):60 Hz 230 … 240 V
              50 Hz 220 … 230 V
            • Coil Consumption:Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
              Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
              Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
              Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
            • Operate Time:Between Coil Energization and NO Contact Closing 10 … 25 ms
              Between Coil De-energization and NC Contact Closing 7 … 15 ms
            • Connecting Capacity Main Circuit:Flexible with Cable End 2x6…35 mm²
              Bar 30 mm²
              Rigid 2x6…65 mm²
            • Connecting Capacity Auxiliary Circuit:Solid 2x1…4 mm²
              Flexible with Insulated Ferrule 2x0.75…2.5 mm²
              Stranded 2x1…4 mm²
              Flexible 2x0.75…2.5 mm²
              Flexible with Ferrule 1x0.75…2.5 mm²
            • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
              acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
            • Connecting terminals (delivered in open position) Main poles:M8 hexagon socket screw with single connector
            • Terminal Type:Cable Clamp
            Environmental
            • Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
              Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
              Close to Contactor for Storage -60…+80 °C

                ABB AF205-30-11 Contactor

                Request Callback

                ₹ 9680 / Unit Get Latest Price

                Voltage220-230V
                Current205 Amps
                BrandABB
                Model NumberAF205-30-11

                Minimum order quantity: 1 Unit

                • General Information
                • Extended Product Type:AF205-30-11-(11/12/13)
                • Product ID:1SFL527002R1311
                • Catalog Description:AF205-30-11 Contactor
                • Long Description:A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC
                Dimension
                • Product Net Width:105.0 mm
                • Product Net Depth:152.0 mm
                • Product Net Height:196.0 mm
                • Product Net Weight:2.778 kg
                Specification
                • Number of Main Contacts NO:3
                • Number of Main Contacts NC:0
                • Number of Auxiliary Contacts NO:1
                • Number of Auxiliary Contacts NC:1
                • Rated Operational Voltage:Main Circuit 1000 V
                • Rated Frequency (f):Main Circuit 50/60 HzConventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
                • Rated Operational Current AC-1 (Ie):(690 V) 55 °C 300 A,(690 V) 40 °C 350 A,(1000 V) 40 °C 275 A,(1000 V) 55 °C 250 A,(690 V) 70 °C 240 A,(1000 V) 70 °C 200 A.
                • Rated Operational Current AC-1 (Ie):(690 V) 55 °C 300 A,(690 V) 40 °C 350 A,(1000 V) 40 °C 275 A,(1000 V) 55 °C 250 A,(690 V) 70 °C 240 A,(1000 V) 70 °C 200 A.
                • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A,cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
                • Maximum Electrical Switching Frequency:AC-3 300 cycles per hour,AC-1 300 cycles per hour,AC-2 / AC-4 150 cycles per hour,
                • Rated Operational Current DC-1 (Ie):(110 V) 2 Poles in Series, 40 °C 275 A(220 V) 3 Poles in Series, 40 °C 275 A,
                • Rated Operational Current DC-3 (Ie):(110 V) 2 Poles in Series, 40 °C 275 A(220 V) 3 Poles in Series, 40 °C 275 A,
                • Rated Operational Current DC-5 (Ie):(110 V) 2 Poles in Series, 40 °C 275 A,(220 V) 3 Poles in Series, 40 °C 275 A,
                • Rated Insulation Voltage (Ui):acc. to UL/CSA 600 Vacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V,
                • Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
                • Mechanical Durability:5 million
                • Maximum Mechanical Switching Frequency:300 cycles per hour
                • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °CRated
                •  Control Circuit Voltage (Uc):60 Hz 100…250 V50 Hz 100…250 VDC Operation 100…250 V
                • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20,acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
                • Terminal Type:Main Circuit: Bars
                Environmental
                • Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °CClose to Contactor for Storage -40…+70 °C
                • Maximum Operating Altitude Permissible:3000 m
                • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

                ABB A26-30-10 Contactor

                Request Callback

                ₹ 1289 / Unit Get Latest Price

                Voltage TypeAC
                Voltage (V)220
                Number of Poles3 Pole
                220-230v/230-240v50Hz/60Hz

                Minimum order quantity: 1 Unit

                General Information
                • Extended Product Type:A26-30-10 220-230V 50Hz / 230-240V 60Hz
                • Product ID:1SBL241001R8010
                • Catalog Description:A26-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
                • Long Description:A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
                Dimensions
                • Product Net Width:54 mm
                • Product Net Depth:93.6 mm
                • Product Net Height:90 mm
                • Product Net Weight:0.600 kg
                Specification
                • Number of Main Contacts NO:3
                • Number of Main Contacts NC:0
                • Number of Auxiliary Contacts NO:1
                • Number of Auxiliary Contacts NC:0
                • Rated Operational Voltage:Main Circuit 690 V
                • Rated Frequency (f):Supply Circuit 50 Hz
                  Supply Circuit 60 Hz
                • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A
                  acc. to IEC 60947-5-1, q = 40 °C 16 A
                • Rated Operational Current AC-1 (Ie):(690 V) 40 °C 45 A
                  (690 V) 55 °C 40 A
                  (690 V) 70 °C 32 A
                • Rated Operational Current AC-3 (Ie):(220 / 230 / 240 V) 55 °C 26 A
                  (380 / 400 V) 55 °C 26 A
                  (415 V) 55 °C 26 A
                  (440 V) 55 °C 26 A
                  (500 V) 55 °C 22 A
                  (690 V) 55 °C 17 A
                • Rated Operational Power AC-3 (Pe):(220 / 230 / 240 V) 6.5 kW
                  (380 / 400 V) 11 kW
                  (415 V) 11 kW
                  (440 V) 15 kW
                  (500 V) 15 kW
                  (690 V) 15 kW
                • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:8 x Ie AC-3
                • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:10 x Ie AC-3
                • Rated Operational Current AC-15 (Ie):(220 / 240 V) 4 A
                  (24 / 127 V) 6 A
                  (380 / 440 V) 3 A
                  (500 V) 2 A
                  (690 V) 2 A
                • Short-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 A
                  gG Type Fuses 50 A
                • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
                  cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
                • Maximum Electrical Switching Frequency:AC-1 600 cycles per hour
                  AC-2 / AC-4 300 cycles per hour
                  AC-3 1200 cycles per hour
                • Connecting Capacity Main Circuit:Flexible with Cable End 0.75 ... 4 mm²
                  Rigid Cable 1.5 ... 6 mm²
                • Connecting Capacity Auxiliary Circuit:Flexible with Cable End 0.75 ... 2.5 mm²
                  Rigid Cable 1 ... 4 mm²
                • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
                • Connecting terminals (delivered in open position) Main poles:M 4 (+,-) pozidriv 2 screws with cable clamp
                • Terminal Type:Screw Terminals
                Environmental
                  • Ambient Air Temperature:Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
                    Close to Contactor for Storage -60 ... +80 °C
                    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
                    Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
                  • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
                  • Maximum Operating Altitude Permissible:3000 m
                  • Resistance to Shock acc. to IEC 60068-2-27:Shock Direction: A 20 g
                    Closed, Shock Direction: B1 10 g
                    Open, Shock Direction: B1 5 g
                    Shock Direction: B2 15 g
                    Shock Direction: C1 20 g
                    Shock Direction: C2 20 g
                  • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

                  A75-22-00 220-230V 50Hz / 230-240V 60Hz Contactor

                  Request Callback

                  Get Latest Price

                  Number of Poles2 Pole
                  Contactor TypeModular Contactors
                  Electricity TypeAC
                  Usage/ApplicationIndustrial
                  Country of OriginMade in India
                  A75 4-pole contactors are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...) and generally for controlling power circuits up to 690 V AC and 440 V DC.

                  ABB MS 116 Motor Starter

                  Request Callback

                  ₹ 1801 / Unit Get Latest Price

                  BrandABB
                  Voltage240 V
                  PhaseThree Phase
                  Current Rating30 A

                  Minimum order quantity: 1 Unit

                  We are the trader, wholesaler and exporter of ABB MS 116-0.16 TO MS 116-32 These Products are available in Motor Starter.

                  Specifications:
                  • Product Net Width:45 mm
                  • Product Net Height:90 mm
                  • Product Net Depth:85.6 mm
                  • Product Net Weight:0.265 kg
                  • Rated Instantaneous Short-Circuit Current Setting (Ii):20 A
                  • Setting Range:0.10 TO ... 32 A
                  • Rated Operational Power AC-3 (Pe):(400 V)
                  • Three Phase 0.55 kW
                  • Rated Operational Voltage: Main Circuit 690 V AC
                  • Rated Operational Current (Ie):0.10 TO 32 A
                  • Rated Operational Current AC-3 (Ie):0.10 TO 32 A
                  • Rated Frequency (f): Main Circuit 50 Hz
                  • Main Circuit: 60 Hz

                  ABB UA26-30-10RA Contactor

                  Request Callback

                  ₹ 2887 / Unit Get Latest Price

                  Voltage TypeAC
                  Voltage (V)220
                  Power Ratings220-230v
                  BrandABB

                  Minimum order quantity: 1 Unit

                  General Information
                  • Extended Product Type:UA26-30-10RA 220-230V 50Hz / 230-240V 60Hz
                  • Product ID:1SBL241024R8010
                  • Catalog Description:UA26-30-10RA 220-230V 50Hz / 230-240V 60Hz Contactor
                  • Long Description:UA26..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level.
                  Dimensions
                  • Product Net Width:54 mm
                  • Product Net Depth:126.3 mm
                  • Product Net Height:120 mm
                  • Product Net Weight:0.710 kg
                  Specification
                  • Number of Main Contacts NO:3
                  • Number of Main Contacts NC:0
                  • Number of Auxiliary Contacts NO:1
                  • Number of Auxiliary Contacts NC:0
                  • Rated Operational Voltage:Auxiliary Circuit 690 V
                    Main Circuit 690 V
                  • Rated Frequency (f):Supply Circuit 50 Hz
                    Supply Circuit 60 Hz
                  • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-5-1, q = 40 °C 16 A
                  • Rated Operational Current AC-15 (Ie):(220 / 240 V) 4 A
                    (24 / 127 V) 6 A
                    (380 / 440 V) 3 A
                    (500 V) 2 A
                    (690 V) 2 A
                  • Short-Circuit Protective Devices:Auxiliary Circuit - gG Type Fuses 10 A
                    gG Type Fuses 125 A
                  • Maximum Electrical Switching Frequency:240 cycles per hour
                  • Rated Operational Current DC-13 (Ie):(125 V) 1.1 / 138 A
                    (24 V) 6 / 144 A
                    (250 V) 0.55 / 138 A
                    (48 V) 2.8 / 134 A
                    (72 V) 2 / 144 A
                  • Rated Impulse Withstand Voltage (Uimp):8 kV
                  • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
                  • Rated Control Circuit Voltage (Uc):50 Hz 220 … 230 V
                    60 Hz 230 … 240 V
                  • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
                  • Terminal Type:Screw Terminals
                  Environmental
                  • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
                  • Maximum Operating Altitude Permissible:3000 m

                        ABB CA5-04E Contactor

                        Request Callback

                        ₹ 532.5 / Unit Get Latest Price

                        Number of Poles1
                        Mounting TypeFront mount
                        PhaseSingle Phase
                        Rated Voltage220-230V

                        Minimum order quantity: 1 Unit

                        General Information

                        Extended Product Type:CA5-04EProduct ID:1SBN010040R1004Catalog Description:CA5-04E Auxiliary Contact BlockLong Description:CA5-04E Auxiliary Contact Block

                        Dimensions

                        Product Net Weight:0.060 kg

                        Environmental

                        RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

                        Additional Information

                        Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20IIT Publishing Status:Level 0 - Information enabledMaximum Electrical Switching Frequency:1200 cycles per hourMaximum Mechanical Switching Frequency:3600 cycles per hourMechanical Durability:A9 ... A75 10 million

                        A95 ... A110 3 millionMinimum Switching Capacity:A9 ... A75 17 / 5 volt per milliamp

                        A95 ... A110 24 / 50 volt per milliampMounting Position:Front faceNumber of Auxiliary Contacts NC:4Order Multiple:2 piecePower Loss:at Rated Operating Conditions per Pole 0.1 WProduct Main Type:Accessories for Block ContactorsProduct Name:Auxiliary Contact BlockRated Breaking Capacity acc. to IEC 60947-5-1:10 x Ie AC-15Rated Frequency (f):Supply Circuit 50 Hz

                        Supply Circuit 60 HzRated Insulation Voltage (Ui):acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V

                        acc. to UL/CSA 600 VRated Making Capacity acc. to IEC 60947-5-1:10 x Ie AC-15Rated Operational Current AC-15 (Ie):(220 / 240 V) 4 A

                        (24 / 127 V) 6 A

                        (380 / 440 V) 3 A

                        (500 V) 2 A

                        (690 V) 2 ARated Operational Current DC-13 (Ie):(125 V) 0.55 / 69 A

                        (24 V) 6 / 144 A

                        (250 V) 0.3 / 75 A

                        (48 V) 2.8 / 134 A

                        (72 V) 1 / 72 ARated Operational Voltage:Main Circuit 24 V

                        Auxiliary Circuit 690 VRated Short-time Withstand Current (Icw):for 1 s 140.0 ARemarks:100Terminal Type:Screw Terminals

                        NX40E-86

                        Request Callback

                        ₹ 1410 / Piece Get Latest Price

                        Number of Auxiliary Contacts NO:4
                        Number of Auxiliary Contacts NC:0
                        Rated Operational Voltage:Auxiliary Circuit 690 V Main Circuit 690 V
                        Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
                        Rated Control Circuit Voltage (Uc):50 Hz 400 ... 415 V 60 Hz 415 ... 440 V
                        Terminal Type:Screw Terminals

                        Minimum order quantity: 1 Piece

                        Product ID:1SBH901074R8640

                        Catalog Description:NX40E-86 400-415V50Hz/415V-440V60Hz Contactor relay

                        AF09-30-01-11

                        Request Callback

                        ₹ 3700 / Piece Get Latest Price

                        Number of Main Contacts NO:3
                        Number of Main Contacts NC:0
                        Number of Auxiliary Contacts NO:0
                        Number of Auxiliary Contacts NC:1
                        Terminal Type:Screw Terminals
                        Rated Operational Voltage:Auxiliary Circuit 690 V Main Circuit 690 V
                        Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz

                        Minimum order quantity: 1 Piece

                        Product ID:1SBL137001R1101

                        Catalog Description:AF09-30-01-11 24-60V50/60HZ 20-60VDC Contactor

                        ABB Motorized Switch Disconnectors ABB

                        Request Callback

                        ₹ 15000 / Unit Get Latest Price

                        PhaseSingle phase
                        Rated Current2Amp
                        Number of Poles1 Pole+N
                        ColorGrey
                        Country of OriginMade in India

                        Motorized switch disconnectors (type OTM_) are suitable for remote control.

                        The switches can be operated either electrically by using the motor operator or manually by using the handle. The operation, either electrical or manual, can be chosen by the selector switch “Motor/Manual” on the motor operator. Motorized switch-disconnectors consist of the switch-disconnector (type OT) and the motor operator. The OTM range is for 160..2500 Amperes. Designed for safety
                        The motorized switch-disconnectors OTM ensure safe operation, protecting both people and equipment.
                        Designed and based on substantial experience of electrical safety, the switches eliminate the risk of electrical accidents:
                        The frames are made of robust plastic with excellent mechanical and thermal properties.
                        Pole markings as standard
                        Inbuilt safety – eliminating the risk for accidents.

                        Easy, flexible installation


                        The motorized switch-disconnectors OTM offer you flexible cabling options. The high terminal positioning with space to the back plate
                        simplifies the mounting of cables. It’s also ideal for double cabling, which in turn saves on space.
                        Reduced installation time reduces cost.

                        Suitable for remote locations - Connectivity to automation system


                        The OTM motorized switch-disconnectors can be operated remotely by using a suitable device e.g. push-buttons or a cam switch.
                        It is also easy to control the motor operator for example with PLC or PC-based controller.
                        Increased productivity.

                        High electrical ratings
                        High Ui ratings
                        High CTI in supporting parts
                        The powerful construction in motorized switch-disconnectors OTM, with their quick-make and quick-break operation features and two contact points instead of one
                        Suitable for numerous applications.

                        Switch Disconnectors - OT

                        Request Callback

                        ₹ 4000 / Unit Get Latest Price

                        BrandABB
                        Pack1
                        ColorGrey
                        Voltage220 V
                        Power16 to 160 Amp
                        he switch-dis connector is largely used as the main switch in low voltage switchgear for distribution of power, starting and stopping motors and isolating loads during maintenance. They are also enclosed in metal or plastic boxes as safety switches to ensure that accidental start of machines is prevented. The range from 16 to 160 Amp are either base plate or door mounted by snap-on or screw fitting. Front operated 3-, 4-, 6-, 8-pole and change over types are available as standard. From 200 up to 3150 Amp the switch-disconnectors, also called load break switches, are designed as pole modules and they are available as 1- to 4-pole versions, front or side operated.

                        ABB 3 Pole Contactor

                        Request Callback

                        ₹ 648 / Unit Get Latest Price

                        Contactor TypeVacuum Contactors
                        Number of Poles2 Pole
                        Voltage TypeAC
                        Voltage (V)220

                        Minimum order quantity: 1 Unit

                        We are the trader, wholesaler and exporter of ABB A09-30-10 TO A185-30-11 These Products are available in 3 Pole Contactors . Specifications:
                        • Product Net Width:44
                        • Product Net Height:74 mm
                        • Product Net Depth:74 mm
                        • Product Net Weight:0.340 kg
                        • Rated Operational Power AC-3 (Pe):(400 V)
                        • Three Phase 2.2 kW
                        • Rated Operational Voltage: Main Circuit 690 V AC
                        • Rated Operational Current AC-3 (Ie):0.10 TO 32 A
                        • Rated Frequency (f): Main Circuit 50 Hz
                        • Main Circuit: 60 Hz
                        Get Best Price Of ABB Contactor 3 pole Fpr Rs.648/-

                        ABB CAL19-11 Contactors

                        Request Callback

                        ₹ 422 / Unit Get Latest Price

                        Number of Poles2
                        Mounting TypeSide mounted
                        PhaseThree Phase
                        Rated Voltage220-230V

                        Minimum order quantity: 1 Unit

                        General Information

                        Extended Product Type:CAL19-11Product ID:1SFN010820R1011Catalog Description:CAL19-11 Auxiliary Contact BlockLong Description:Auxiliary contact block for contactors AF116…AF370
                        Dimensions
                        Product Net Weight:0.040 kg
                        Environmental
                        Battery Information:Type NONERoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
                        Specification

                        Product Name:Auxiliary Contact BlockRoHS Date:1226 1Suitable For:AF116
                        AF140
                        AF146
                        AF190
                        AF205
                        AF265
                        AF305
                        AF370Suitable for Product Class:CONTACTORSTerminal Type:Screw Terminals

                        ABB UA75-30-00 Contactor

                        Request Callback

                        ₹ 8378 / Unit Get Latest Price

                        Voltage TypeAC
                        Number of Poles3 Pole
                        BrandABB
                        Power Ratings220-230v

                        Minimum order quantity: 1 Unit

                        General Information
                        • Extended Product Type:UA75-30-00RA 220-230V 50Hz / 230-240V 60Hz
                        • Product ID:1SBL411024R8000
                        • Catalog Description:UA75-30-00RA 220-230V 50Hz / 230-240V 60Hz Contactor
                        • Long Description:UA75..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles: 3 main poles - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
                        Dimensions
                        • Product Net Width:70 mm
                        • Product Net Depth:140.4 mm
                        • Product Net Height:150 mm
                        • Product Net Weight:1.350 kg
                        Technical
                        • Number of Main Contacts NO:3
                        • Rated Operational Voltage:Main Circuit 690 V
                        • Short-Circuit Protective Devices:gG Type Fuses 200 A
                        • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
                          cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
                        • Maximum Electrical Switching Frequency:240 cycles per hour
                        • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
                          acc. to UL/CSA 600 V
                        • Rated Impulse Withstand Voltage (Uimp):8 kV
                        • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
                        • Rated Control Circuit Voltage (Uc):50 Hz 220 … 230 V
                          60 Hz 230 … 240 V
                        • Operate Time:Between Coil Energization and NO Contact Closing 8 ... 27 ms
                          Between Coil De-energization and NO Contact Opening 4 ... 11 ms
                        • Connecting Capacity Main Circuit:Rigid Cable 6 ... 16 mm²
                          Flexible with Cable End 6 ... 10 mm²
                        • Connecting Capacity Auxiliary Circuit:Rigid Cable 1 ... 4 mm²
                          Flexible with Cable End 0.75 ... 2.5 mm²
                        • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
                        • Connecting terminals (delivered in open position) Main poles:M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
                        • Terminal Type:Screw Terminals
                        Environmental
                        • Ambient Air Temperature:Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C,Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C,Close to Contactor for Storage -60 ... +80 °C
                        • Climatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
                        • Maximum Operating Altitude Permissible:3000 m
                        • RoHS Status:No declaration needed