ABB Control Product

Leading Distributor / Channel Partner of abb ck1-20( signaling contact- right), abb ta25du 1.4m ( thermal overload relay), abb ta25du 1.8m ( thermal overload relay), abb ta25du 2.4m ( thermal overload relay), abb ta25du 3.1m( thermal overload relay) and abb ta25du 4.0m( thermal overload relay) from Coimbatore.

ABB CK1-20( Signaling Contact- Right)

ABB CK1-20( Signaling Contact- Right)
  • ABB CK1-20( Signaling Contact- Right)
Get Best Quote
Approx. Price: Rs 979 / UnitGet Latest Price

Product Details:

Minimum Order Quantity1 Unit
Starter Type Semi Automatic Star Delta Starter
Coil Voltage 120 V
Current Rating 30 A
Phase Three Phase
SUITABLE FORMS132

General Information
  • Extended Product Type:CK1-20
  • Product ID:1SAM301901R1002
  • Catalog Description:CK1-20 Short Circuit Signaling Contact
  • Long Description:CK1-20 Short-Circuit Signal Contact 1 NO+1 NC
Dimensions
  • Product Net Width:9 mm
  • Product Net Height:90 mm
  • Product Net Depth:78 mm
  • Product Net Weight:0.035 kg
Specification
  • Rated Operational Voltage:690 V AC
    600 V DC
    Main Circuit 690 V
  • Rated Operational Current AC-15 (Ie):(240 V) 4 A
    (24 V) 6 A
    (380 / 400 V) 3 A
    (690 V) 1 A
  • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
    (24 V) 2 A
    (250 V) 0.27 A
    (440 V) 0 A
    (600 V) 0 A
  • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
  • Rated Insulation Voltage (Ui):690 V
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
    Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
    Flexible 1/2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1 ... 1.5 mm²
  • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:Auxiliary Circuit 8 mm
  • Recommended Screw Driver:M3
    Pozidriv 2
  • Number of Auxiliary Contacts NO:2
  • Number of Auxiliary Contacts NC:0
  • Standards:IEC/EN 60947-1
    IEC/EN 60947-2
    IEC/EN 60947-4-1
    IEC/EN 60947-5-1
    UL 508
    CSA 22.2 No. 14
  • Product Name:Short Circuit Signaling Contact
  • Suitable For:MS132
  • Suitable for Product Class:Manual Motor Starter
Environmental
  • RoHS Status:Following EU Directive 2011/65/EC
    Request
    Callback


    Additional Information:

    • Item Code: 1SAM301901R1002
    • Pay Mode Terms: T/T (Bank Transfer)
    Send Business Enquiry

    ABB TA25DU 1.4M ( Thermal Overload Relay)

    ABB TA25DU 1.4M ( Thermal Overload Relay)
    • ABB TA25DU 1.4M ( Thermal Overload Relay)
    Get Best Quote
    Approx. Price: Rs 887 / UnitGet Latest Price

    Product Details:

    Minimum Order Quantity1 Unit
    Voltage (V)415V
    Voltage TypeAC
    Number of Poles3 Pole
    Current (Amps)1.0-1.4Amps
    Applicationprotect from overload and phase loss

    General Information
    • Extended Product Type:TA25DU-1.4M
    • Product ID:1SAZ211201R2023
    • Catalog Description:TA25DU-1.4M Thermal Overload Relays
    • Long Description:TA25DU-1.4M (1.0-1.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
    Dimensions
    • Product Net Width:44 mm
    • Product Net Height:80 mm
    • Product Net Depth:94 mm
    • Product Net Weight:0.15 kg
    Specification
    • Setting Range:1.00 ... 1.40 A
    • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
      Main Circuit 690 V AC
    • Rated Operational Current (Ie):1.4 A
    • Rated Operational Current AC-3 (Ie):1.4 A
    • Rated Frequency (f):Auxiliary Circuit 50 Hz
      Auxiliary Circuit 60 Hz
      Auxiliary Circuit DC
      Main Circuit 60 Hz
      Main Circuit 50 Hz
      Main Circuit DC
    • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
      Main Circuit 6 kV
    • Rated Insulation Voltage (Ui):690 V
    • Number of Poles:3
    • Number of Auxiliary Contacts NC:1
    • Number of Auxiliary Contacts NO:1
    • Number of Protected Poles:3
    • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
      Auxiliary Circuit NO 5 A
    • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
      (120 V) NO 1.500 A
      (240 V) NC 3.000 A
      (240 V) NO 1.500 A
      (400 V) NC 1.900 A
      (400 V) NO 1.000 A
      (440 V) NC 1.000 A
      (440 V) NO 1.000 A
      (500 V) NC 1.000 A
      (500 V) NO 1.000 A
    • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
      (125 V) NO 0.250 A
      (24 V) NC 1.250 A
      (24 V) NO 1.250 A
      (250 V) NC 0.120 A
      (250 V) NO 0.040 A
      (60 V) NC 0.250 A
      (60 V) NO 0.250 A
    • Degree of Protection:Housing IP20
      Main Circuit Terminals IP10
    • Pollution Degree:3
    • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
      Rigid 1/2x 0.75 ... 4 mm²
    • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
      Flexible with Ferrule 2x 0.75 ... 4 mm²
      Flexible 1x 0.75 ... 4 mm²
      Flexible 2x 0.75 ... 4 mm²
      Rigid 1x 0.75 ... 4 mm²
      Rigid 2x 0.75 ... 4 mm²
    • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
      Main Circuit 1.5 ... 1.9 N·m
    • Wire Stripping Length:Auxiliary Circuit 9 mm
      Main Circuit 12 mm
    • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
      Main Circuit Pozidriv 2
    • Mounting Position:Position 1 to 4
    • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
    • Suitable For:AX09
      AX12
      AX18
      AX25
      AX32
      AX40
    • Standards:IEC/EN 60947-1
      IEC/EN 60947-4-1
      IEC/EN 60947-5-1
      UL 508
      CSA 22.2 No. 14
    Environmental
    • Ambient Air Temperature:Operation -25 ... +55 °C
      Operation Compensated -25 ... +55 °C
      Storage -40 ... +70 °C
    • Ambient Air Temperature Compensation:Yes
    • Maximum Operating Altitude Permissible:2000 m
    • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
    • RoHS Status:Following EU Directive 2011/65/EC
      Request
      Callback


      Additional Information:

      • Item Code: 1SAZ211201R2023
      • Pay Mode Terms: T/T (Bank Transfer)
      Send Business Enquiry

      ABB TA25DU 1.8M ( Thermal Overload Relay)

      ABB TA25DU 1.8M ( Thermal Overload Relay)
      • ABB TA25DU 1.8M ( Thermal Overload Relay)
      Get Best Quote
      Approx. Price: Rs 887 / UnitGet Latest Price

      Product Details:

      Minimum Order Quantity1 Unit
      Voltage (V)415v
      Voltage TypeAC
      Number of Poles3 Pole
      Current (Amps)1.3-1.8Amps
      Applicationprotect from overload and phase loss

      General Information
      • Extended Product Type:TA25DU-1.8M
      • Product ID:1SAZ211201R2025
      • Catalog Description:TA25DU-1.8M Thermal Overload Relays
      • Long Description:TA25DU-1.8M (1.3-1.8A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
      Dimensions
      • Product Net Width:44 mm
      • Product Net Height:80 mm
      • Product Net Depth:94 mm
      • Product Net Weight:0.15 kg
      Specification
      • Setting Range:1.30 ... 1.80 A
      • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
        Main Circuit 690 V AC
      • Rated Operational Current (Ie):1.8 A
      • Rated Operational Current AC-3 (Ie):1.8 A
      • Rated Frequency (f):Auxiliary Circuit 50 Hz
        Auxiliary Circuit 60 Hz
        Auxiliary Circuit DC
        Main Circuit 60 Hz
        Main Circuit 50 Hz
        Main Circuit DC
      • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
        Main Circuit 6 kV
      • Rated Insulation Voltage (Ui):690 V
      • Number of Poles:3
      • Number of Auxiliary Contacts NC:1
      • Number of Auxiliary Contacts NO:1
      • Number of Protected Poles:3
      • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
        Auxiliary Circuit NO 5 A
      • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
        (120 V) NO 1.500 A
        (240 V) NC 3.000 A
        (240 V) NO 1.500 A
        (400 V) NC 1.900 A
        (400 V) NO 1.000 A
        (440 V) NC 1.000 A
        (440 V) NO 1.000 A
        (500 V) NC 1.000 A
        (500 V) NO 1.000 A
      • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
        (125 V) NO 0.250 A
        (24 V) NC 1.250 A
        (24 V) NO 1.250 A
        (250 V) NC 0.120 A
        (250 V) NO 0.040 A
        (60 V) NC 0.250 A
        (60 V) NO 0.250 A
      • Degree of Protection:Housing IP20
        Main Circuit Terminals IP10
      • Pollution Degree:3
      • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
        Rigid 1/2x 0.75 ... 4 mm²
      • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
        Flexible with Ferrule 2x 0.75 ... 4 mm²
        Flexible 1x 0.75 ... 4 mm²
        Flexible 2x 0.75 ... 4 mm²
        Rigid 1x 0.75 ... 4 mm²
        Rigid 2x 0.75 ... 4 mm²
      • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
        Main Circuit 1.5 ... 1.9 N·m
      • Wire Stripping Length:Auxiliary Circuit 9 mm
        Main Circuit 12 mm
      • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
        Main Circuit Pozidriv 2
      • Mounting Position:Position 1 to 4
      • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
      • Suitable For:AX09
        AX12
        AX18
        AX25
        AX32
        AX40
      • Standards:IEC/EN 60947-1
        IEC/EN 60947-4-1
        IEC/EN 60947-5-1
        UL 508
        CSA 22.2 No. 14
      Environmental
      • Ambient Air Temperature:Operation -25 ... +55 °C
        Operation Compensated -25 ... +55 °C
        Storage -40 ... +70 °C
      • Ambient Air Temperature Compensation:Yes
      • Maximum Operating Altitude Permissible:2000 m
      • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
      • RoHS Status:Following EU Directive 2011/65/EC
        Request
        Callback


        Additional Information:

        • Item Code: 1SAZ211201R2025
        • Pay Mode Terms: T/T (Bank Transfer)
        Send Business Enquiry

        ABB TA25DU 2.4M ( Thermal Overload Relay)

        ABB TA25DU 2.4M ( Thermal Overload Relay)
        • ABB TA25DU 2.4M ( Thermal Overload Relay)
        Get Best Quote
        Approx. Price: Rs 887 / UnitGet Latest Price

        Product Details:

        Minimum Order Quantity1 Unit
        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)1.7-2.4Amps
        Applicationprotect from phase loss and overload

        General Information
        • Extended Product Type:TA25DU-2.4M
        • Product ID:1SAZ211201R2028
        • Catalog Description:TA25DU-2.4M Thermal Overload Relays
        • Long Description:TA25DU-2.4M (1.7-2.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:44 mm
        • Product Net Height:80 mm
        • Product Net Depth:94 mm
        • Product Net Weight:0.15 kg
        Specification
        • Setting Range:1.70 ... 2.40 A
        • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):2.4 A
        • Rated Operational Current AC-3 (Ie):2.4 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
          (120 V) NO 1.500 A
          (240 V) NC 3.000 A
          (240 V) NO 1.500 A
          (400 V) NC 1.900 A
          (400 V) NO 1.000 A
          (440 V) NC 1.000 A
          (440 V) NO 1.000 A
          (500 V) NC 1.000 A
          (500 V) NO 1.000 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
          (125 V) NO 0.250 A
          (24 V) NC 1.250 A
          (24 V) NO 1.250 A
          (250 V) NC 0.120 A
          (250 V) NO 0.040 A
          (60 V) NC 0.250 A
          (60 V) NO 0.250 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
          Flexible with Ferrule 2x 0.75 ... 4 mm²
          Flexible 1x 0.75 ... 4 mm²
          Flexible 2x 0.75 ... 4 mm²
          Rigid 1x 0.75 ... 4 mm²
          Rigid 2x 0.75 ... 4 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 1.5 ... 1.9 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 12 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
        • Suitable For:AX09
          AX12
          AX18
          AX25
          AX32
          AX40
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 508
          CSA 22.2 No. 14
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2028
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 3.1M( Thermal Overload Relay)

          ABB TA25DU 3.1M( Thermal Overload Relay)
          • ABB TA25DU 3.1M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)2.2-3.1Amps
          Applicationprotect from overload and phase loss

          General Information
          • Extended Product Type:TA25DU-3.1M
          • Product ID:1SAZ211201R2031
          • Catalog Description:TA25DU-3.1M Thermal Overload Relays
          • Long Description:TA25DU-3.1M (2.2-3.1A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:2.20 ... 3.10 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):3.1 A
          • Rated Operational Current AC-3 (Ie):3.1 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2031
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 4.0M( Thermal Overload Relay)

          ABB TA25DU  4.0M( Thermal Overload Relay)
          • ABB TA25DU  4.0M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415v
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)2.8-4.0Amps
          Applicationprotect from overload and phase loss

          General Information
          • Extended Product Type:TA25DU-4.0M
          • Product ID:1SAZ211201R2033
          • Catalog Description:TA25DU-4.0M Thermal Overload Relays
          • Long Description:TA25DU-4.0M (2.8-4.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:2.80 ... 4.00 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):4 A
          • Rated Operational Current AC-3 (Ie):4 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2033
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 5.0M ( Thermal Overload Relay)

          ABB TA25DU 5.0M ( Thermal Overload Relay)
          • ABB TA25DU 5.0M ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)3.5-5.0Amps
          Applicationprotect from overload and phase loss

          General Information
          • Extended Product Type:TA25DU-5.0M
          • Product ID:1SAZ211201R2035
          • Catalog Description:TA25DU-5.0M Thermal Overload Relays
          • Long Description:TA25DU-5.0M (3.5-5.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:3.50 ... 5.00 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):5 A
          • Rated Operational Current AC-3 (Ie):5 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2035
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 6.5M( Thermal Overload Relay)

          ABB TA25DU 6.5M( Thermal Overload Relay)
          • ABB TA25DU 6.5M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415v
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)4.5-6.5Amps
          Applicationprotect from overload and phase loss

          General Information
          • Extended Product Type:TA25DU-6.5M
          • Product ID:1SAZ211201R2038
          • Catalog Description:TA25DU-6.5M Thermal Overload Relays
          • Long Description:TA25DU-6.5M (4.5-6.5A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:4.50 ... 6.50 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):6.5 A
          • Rated Operational Current AC-3 (Ie):6.5 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2038
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 8.5M( Thermal Overload Relay)

          ABB TA25DU 8.5M( Thermal Overload Relay)
          • ABB TA25DU 8.5M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)6.0-8.5Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA25DU-8.5M
          • Product ID:1SAZ211201R2040
          • Catalog Description:TA25DU-8.5M Thermal Overload Relays
          • Long Description:TA25DU-8.5M (6.0-8.5A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:6.00 ... 8.50 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):8.5 A
          • Rated Operational Current AC-3 (Ie):8.5 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2040
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 11M ( Thermal Overload Relay)

          ABB TA25DU 11M  ( Thermal Overload Relay)
          • ABB TA25DU 11M  ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)7.50-11.0Amps
          Applicationprotect from overload and phase loss

          General Information
          • Extended Product Type:TA25DU-11M
          • Product ID:1SAZ211201R2043
          • Catalog Description:TA25DU-11M Thermal Overload Relays
          • Long Description:TA25DU-11M (7.5-11A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:7.50 ... 11.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):11 A
          • Rated Operational Current AC-3 (Ie):11 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2043
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 14M( Thermal Overload Relay)

          ABB TA25DU 14M( Thermal Overload Relay)
          • ABB TA25DU 14M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 887 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)10.0-14.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA25DU-14M
          • Product ID:1SAZ211201R2045
          • Catalog Description:TA25DU-14M Thermal Overload Relays
          • Long Description:TA25DU-14M (10.0-14.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:10.0 ... 14.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):14 A
          • Rated Operational Current AC-3 (Ie):14 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.2 ... 2.4 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2045
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 25M ( Thermal Overload Relay)

          ABB TA25DU 25M  ( Thermal Overload Relay)
          • ABB TA25DU 25M  ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 1,098 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)18.0-25.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA25DU-25M
          • Product ID:1SAZ211201R2051
          • Catalog Description:TA25DU-25M Thermal Overload Relays
          • Long Description:TA25DU-25M (18.0-25A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.17 kg
          Specification
          • Setting Range:18.0 ... 25.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):25 A
          • Rated Operational Current AC-3 (Ie):25 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 2.9 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2051
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA25DU 32M(Thermal Overload Relay)

          ABB TA25DU 32M(Thermal Overload Relay)
          • ABB TA25DU 32M(Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 1,535 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415v
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)24.0-32.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA25DU-32M
          • Product ID:1SAZ211201R2053
          • Catalog Description:TA25DU-32M Thermal Overload Relays
          • Long Description:TA25DU-32M (24.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.2 kg
          Specification
          • Setting Range:24.0 ... 32.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):32 A
          • Rated Operational Current AC-3 (Ie):32 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 2.5 ... 3.2 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 15 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.8 ... 3.3 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ211201R2053
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA42DU 25( Thermal Overload Relay)

          ABB TA42DU 25( Thermal Overload Relay)
          • ABB TA42DU 25( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 1,824 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)18.0-25.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA42DU-25M
          • Product ID:1SAZ311201R2001
          • Catalog Description:TA42DU-25M Thermal Overload Relays
          • Long Description:TA42DU-25M (18.0-25.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:18.0 ... 25.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):25 A
          • Rated Operational Current AC-3 (Ie):25 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.8 ... 3.4 W
          • Suitable For:AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ311201R2001
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA42DU 32 ( Thermal Overload Relay)

          ABB TA42DU 32 ( Thermal Overload Relay)
          • ABB TA42DU 32 ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 1,993 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)22.0-32.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA42DU-32M
          • Product ID:1SAZ311201R2002
          • Catalog Description:TA42DU-32M Thermal Overload Relays
          • Long Description:TA42DU-32M (22.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:22.0 ... 32.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):32 A
          • Rated Operational Current AC-3 (Ie):32 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.4 ... 3.0 W
          • Suitable For:AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ311201R2002
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA42DU 42( Thermal Overload Relay)

          ABB TA42DU 42( Thermal Overload Relay)
          • ABB TA42DU 42( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,014 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)29.0-42.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA42DU-42M
          • Product ID:1SAZ311201R2003
          • Catalog Description:TA42DU-42M Thermal Overload Relays
          • Long Description:TA42DU-42M (29.0-42.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:29.0 ... 42.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):42 A
          • Rated Operational Current AC-3 (Ie):42 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 3.2 W
          • Suitable For:AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ311201R2003
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA75DU 32M ( Thermal Overload Relay)

          ABB TA75DU 32M ( Thermal Overload Relay)
          • ABB TA75DU 32M ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,302 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)440v
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)22.0-32.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA75DU-32M
          • Product ID:1SAZ321201R2002
          • Catalog Description:TA75DU-32M Thermal Overload Relays
          • Long Description:TA75DU-32M (22.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:22.0 ... 32.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):32 A
          • Rated Operational Current AC-3 (Ie):32 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.4 ... 3.0 W
          • Suitable For:AX50
            AX65
            AX80
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ321201R2002
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA75DU 42M ( Thermal Overload Relay)

          ABB TA75DU 42M ( Thermal Overload Relay)
          • ABB TA75DU 42M ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,703 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)29.0-42.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA75DU-42M
          • Product ID:1SAZ321201R2003
          • Catalog Description:TA75DU-42M Thermal Overload Relays
          • Long Description:TA75DU-42M (29.0-42.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:29.0 ... 42.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):42 A
          • Rated Operational Current AC-3 (Ie):42 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 3.2 W
          • Suitable For:AX50
            AX65
            AX80
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ321201R2003
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA75DU 52M ( Thermal Overload Relay)

          ABB TA75DU 52M ( Thermal Overload Relay)
          • ABB TA75DU 52M ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,703 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)36.0-52.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA75DU-52M
          • Product ID:1SAZ321201R2004
          • Catalog Description:TA75DU-52M Thermal Overload Relays
          • Long Description:TA75DU-52M (36.0-52.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:36.0 ... 52.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):52 A
          • Rated Operational Current AC-3 (Ie):52 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.7 ... 3.5 W
          • Suitable For:AX50
            AX65
            AX80
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ321201R2004
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA75DU 63M ( Thermal Overload Relay)

          ABB TA75DU 63M ( Thermal Overload Relay)
          • ABB TA75DU 63M ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,703 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)45.0-63.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA75DU-63M
          • Product ID:1SAZ321201R2005
          • Catalog Description:TA75DU-63M Thermal Overload Relays
          • Long Description:TA75DU-63M (45.0-63.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.335 kg
          Specification
          • Setting Range:45.0 ... 63.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):63 A
          • Rated Operational Current AC-3 (Ie):63 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.9 ... 3.8 W
          • Suitable For:AX50
            AX65
            AX80
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ321201R2005
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA75DU 80M( Thermal Overload Relay)

          ABB TA75DU 80M( Thermal Overload Relay)
          • ABB TA75DU 80M( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,901 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)60.0-80.0Amps
          Applicationprotect from phase loss and overload

          General Information
          • Extended Product Type:TA75DU-80M
          • Product ID:1SAZ321201R2006
          • Catalog Description:TA75DU-80M Thermal Overload Relays
          • Long Description:TA75DU-80M (60.0-80.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:54 mm
          • Product Net Height:90 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.37 kg
          Specification
          • Setting Range:60.0 ... 80.0 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):80 A
          • Rated Operational Current AC-3 (Ie):80 A
          • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
            Main Circuit DC/50/60 Hz
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP20
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Main Circuit 1 ... 1.3 N·m
            Main Circuit AuxiliaryCircuit4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 2.5 ... 4.4 W
          • Suitable For:AX50
            AX65
            AX80
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          Request
          Callback


          Additional Information:

          • Item Code: 1SAZ321201R2006
          • Pay Mode Terms: T/T (Bank Transfer)
          Send Business Enquiry

          ABB TA80DU-52 ( Thermal Overload Relay)

          ABB TA80DU-52 ( Thermal Overload Relay)
          • ABB TA80DU-52 ( Thermal Overload Relay)
          Get Best Quote
          Approx. Price: Rs 2,978 / UnitGet Latest Price

          Product Details:

          Minimum Order Quantity1 Unit
          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)36.0-52.0Amps
          ApplicationProtect from phase loss and overload

          General Information
          • Extended Product Type:TA80DU-52
          • Product ID:1SAZ331201R1004
          • Catalog Description:TA80DU-52 Thermal Overload Relay
          • Long Description:The TA80DU-52 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:78 mm
          • Product Net Height:97 mm
          • Product Net Depth:111 mm
          • Product Net Weight:0.365 kg
          Specification
          • Setting Range:36 ... 52 A
          • Rated Operational Voltage:Auxiliary Circuit 440 V DC
            Auxiliary Circuit 500 V AC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):52 A
          • Rated Operational Current AC-3 (Ie):52 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
            (120 V) NO 1.5 A
            (240 V) NC 3 A
            (240 V) NO 1.5 A
            (400 V) NC 1.9 A
            (400 V) NO 1 A
            (440 V) NC 1 A
            (440 V) NO 1 A
            (500 V) NC 1 A
            (500 V) NO 1 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
            (125 V) NO 0.25 A
            (24 V) NC 1.25 A
            (24 V) NO 1.25 A
            (250 V) NC 0.12 A
            (250 V) NO 0.04 A
            (60 V) NC 0.25 A
            (60 V) NO 0.25 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
            Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
            Flexible with Ferrule 2x 2.5 ... 10 mm²
            Rigid 1x 2.5 ... 25 mm²
            Rigid 2x 2.5 ... 16 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 4.5 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 14 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.7 ... 3.5 W
          • Suitable For:A95
            A110
            AE95
            AE110
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 60947-1
            UL 60947-4-1
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC
          .
            Request
            Callback


            Additional Information:

            • Item Code: 1SAZ331201R1004
            • Pay Mode Terms: T/T (Bank Transfer)
            Send Business Enquiry

            ABB TA80DU 63 ( Thermal Overload Relay)

            ABB TA80DU 63 ( Thermal Overload Relay)
            • ABB TA80DU 63 ( Thermal Overload Relay)
            Get Best Quote
            Approx. Price: Rs 2,978 / UnitGet Latest Price

            Product Details:

            Minimum Order Quantity1 Unit
            Voltage (V)415V
            Voltage TypeAC
            Number of Poles3 Pole
            Current (Amps)45.0-63.0Amps
            Applicationprotect from phase loss and overload

            General Information
            • Extended Product Type:TA80DU-63
            • Product ID:1SAZ331201R1005
            • Catalog Description:TA80DU-63 Thermal Overload Relay
            • Long Description:The TA80DU-63 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
            Dimensions
            • Product Net Width:78 mm
            • Product Net Height:97 mm
            • Product Net Depth:111 mm
            • Product Net Weight:0.365 kg
            Specification
            • Setting Range:45 ... 63 A
            • Rated Operational Voltage:Auxiliary Circuit 440 V DC
              Auxiliary Circuit 500 V AC
              Main Circuit 690 V AC
            • Rated Operational Current (Ie):63 A
            • Rated Operational Current AC-3 (Ie):63 A
            • Rated Frequency (f):Auxiliary Circuit 50 Hz
              Auxiliary Circuit 60 Hz
              Auxiliary Circuit DC
              Main Circuit 60 Hz
              Main Circuit 50 Hz
              Main Circuit DC
            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
              Main Circuit 6 kV
            • Rated Insulation Voltage (Ui):690 V
            • Number of Poles:3
            • Number of Auxiliary Contacts NC:1
            • Number of Auxiliary Contacts NO:1
            • Number of Protected Poles:3
            • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
              Auxiliary Circuit NO 5 A
            • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
              (120 V) NO 1.5 A
              (240 V) NC 3 A
              (240 V) NO 1.5 A
              (400 V) NC 1.9 A
              (400 V) NO 1 A
              (440 V) NC 1 A
              (440 V) NO 1 A
              (500 V) NC 1 A
              (500 V) NO 1 A
            • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
              (125 V) NO 0.25 A
              (24 V) NC 1.25 A
              (24 V) NO 1.25 A
              (250 V) NC 0.12 A
              (250 V) NO 0.04 A
              (60 V) NC 0.25 A
              (60 V) NO 0.25 A
            • Degree of Protection:Housing IP20
              Main Circuit Terminals IP10
            • Pollution Degree:3
            • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
              Flexible 1/2x 0.75 ... 2.5 mm²
              Rigid 1/2x 0.75 ... 4 mm²
            • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
              Flexible with Ferrule 2x 2.5 ... 10 mm²
              Rigid 1x 2.5 ... 25 mm²
              Rigid 2x 2.5 ... 16 mm²
            • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
              Main Circuit 4.5 N·m
            • Wire Stripping Length:Auxiliary Circuit 9 mm
              Main Circuit 14 mm
            • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
              Main Circuit Pozidriv 2
            • Mounting Position:Position 1 to 4
            • Power Loss:at Rated Operating Conditions per Pole 1.9 ... 3.8 W
            • Suitable For:A95
              A110
              AE95
              AE110
            • Standards:IEC/EN 60947-1
              IEC/EN 60947-4-1
              IEC/EN 60947-5-1
              UL 60947-1
              UL 60947-4-1
            Environmental
            • Ambient Air Temperature:Operation -25 ... +55 °C
              Operation Compensated -25 ... +55 °C
              Storage -40 ... +70 °C
            • Ambient Air Temperature Compensation:Yes
            • Maximum Operating Altitude Permissible:2000 m
            • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
            • RoHS Status:Following EU Directive 2011/65/EC
            Request
            Callback


            Additional Information:

            • Item Code: 1SAZ331201R1005
            • Pay Mode Terms: T/T (Bank Transfer)
            Send Business Enquiry

            ABB TA80DU 80 (Thermal Overload Relay)

            ABB TA80DU 80 (Thermal Overload Relay)
            • ABB TA80DU 80 (Thermal Overload Relay)
            Get Best Quote
            Approx. Price: Rs 3,197 / UnitGet Latest Price

            Product Details:

            Minimum Order Quantity1 Unit
            Voltage (V)415V
            Voltage TypeAC
            Number of Poles3 Pole
            Current (Amps)60.0-80.0Amps
            Applicationprotect from phase loss and overload

            General Information
            • Extended Product Type:TA80DU-80
            • Product ID:1SAZ331201R1006
            • Catalog Description:TA80DU-80 Thermal Overload Relay
            • Long Description:The TA80DU-80 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
            Dimensions
            • Product Net Width:78 mm
            • Product Net Height:97 mm
            • Product Net Depth:111 mm
            • Product Net Weight:0.375 kg
            Specification
            • Setting Range:60 ... 80 A
            • Rated Operational Voltage:Auxiliary Circuit 440 V DC
              Auxiliary Circuit 500 V AC
              Main Circuit 690 V AC
            • Rated Operational Current (Ie):80 A
            • Rated Operational Current AC-3 (Ie):80 A
            • Rated Frequency (f):Auxiliary Circuit 50 Hz
              Auxiliary Circuit 60 Hz
              Auxiliary Circuit DC
              Main Circuit 60 Hz
              Main Circuit 50 Hz
              Main Circuit DC
            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
              Main Circuit 6 kV
            • Rated Insulation Voltage (Ui):690 V
            • Number of Poles:3
            • Number of Auxiliary Contacts NC:1
            • Number of Auxiliary Contacts NO:1
            • Number of Protected Poles:3
            • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
              Auxiliary Circuit NO 5 A
            • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
              (120 V) NO 1.5 A
              (240 V) NC 3 A
              (240 V) NO 1.5 A
              (400 V) NC 1.9 A
              (400 V) NO 1 A
              (440 V) NC 1 A
              (440 V) NO 1 A
              (500 V) NC 1 A
              (500 V) NO 1 A
            • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
              (125 V) NO 0.25 A
              (24 V) NC 1.25 A
              (24 V) NO 1.25 A
              (250 V) NC 0.12 A
              (250 V) NO 0.04 A
              (60 V) NC 0.25 A
              (60 V) NO 0.25 A
            • Degree of Protection:Housing IP20
              Main Circuit Terminals IP10
            • Pollution Degree:3
            • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
              Flexible 1/2x 0.75 ... 2.5 mm²
              Rigid 1/2x 0.75 ... 4 mm²
            • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
              Flexible with Ferrule 2x 2.5 ... 10 mm²
              Rigid 1x 2.5 ... 25 mm²
              Rigid 2x 2.5 ... 16 mm²
            • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
              Main Circuit 4.5 N·m
            • Wire Stripping Length:Auxiliary Circuit 9 mm
              Main Circuit 14 mm
            • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
              Main Circuit Pozidriv 2
            • Mounting Position:Position 1 to 4
            • Power Loss:at Rated Operating Conditions per Pole 2.2 ... 3.9 W
            • Suitable For:A95
              A110
              AE95
              AE110
            • Standards:IEC/EN 60947-1
              IEC/EN 60947-4-1
              IEC/EN 60947-5-1
              UL 60947-1
              UL 60947-4-1
            Environmental
            • Ambient Air Temperature:Operation -25 ... +55 °C
              Operation Compensated -25 ... +55 °C
              Storage -40 ... +70 °C
            • Ambient Air Temperature Compensation:Yes
            • Maximum Operating Altitude Permissible:2000 m
            • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
            • RoHS Status:Following EU Directive 2011/65/EC
            Request
            Callback


            Additional Information:

            • Item Code: 1SAZ331201R1006
            • Pay Mode Terms: T/T (Bank Transfer)
            Send Business Enquiry

            ABB HKF1-01 (Auxiliary Contact-front)

            ABB HKF1-01 (Auxiliary Contact-front)
            • ABB HKF1-01 (Auxiliary Contact-front)
            Get Best Quote
            Approx. Price: Rs 247 / UnitGet Latest Price

            Product Details:

            Minimum Order Quantity1 Unit
            Starter Type Semi Automatic Star Delta Starter
            Coil Voltage 120 V
            Current Rating 40 A
            Suitable for:manual motor starter

            General Information
            • Extended Product Type:HKF1-01
            • Product ID:1SAM201901R1004
            • Catalog Description:HKF1-01 Auxiliary Contact
            • Long Description:HKF1-01 Aux.-contact for front mounting
            Dimensions
            • Product Net Width:45 mm
            • Product Net Height:12.5 mm
            • Product Net Depth:26.5 mm
            • Product Net Weight:0.013 kg
            Specification
            • Rated Operational Voltage:250 V
            • Rated Operational Current AC-15 (Ie):(240 V) 4 A
              (24 V) 6 A
              (380 / 400 V) 3 A
              (690 V) 1 A
            • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
              (24 V) 2 A
              (250 V) 0.27 A
            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            • Rated Insulation Voltage (Ui):250 V
            • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
              Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
              Flexible 1/2x 0.75 ... 1.5 mm²
              Rigid 1/2x 1.0 ... 2.5 mm²
            • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
            • Wire Stripping Length:Auxiliary Circuit 8 mm
            • Recommended Screw Driver:M3
              Pozidriv 2
            • Number of Auxiliary Contacts NC:1
            • Product Name:Auxiliary Contact
            • Suitable For:MS165
              MO165
              MS132
              MO132
              MS116
            Environmental
            • Ambient Air Temperature:Operation -20 ... +55 °C
              Storage -50 ... +80 °C
              Request
              Callback


              Additional Information:

              • Item Code: 1SAM201901R1004
              • Pay Mode Terms: T/T (Bank Transfer)
              Send Business Enquiry

              ABB SK1-02 ( Signaling Contacts- Right)

              ABB SK1-02 ( Signaling Contacts- Right)
              • ABB SK1-02 ( Signaling Contacts- Right)
              Get Best Quote
              Approx. Price: Rs 690 / UnitGet Latest Price

              Product Details:

              Minimum Order Quantity1 Unit
              BrandABB
              Starter TypeSUITABLE FOR MANUAL MOTOR STARTER
              Phase Three Phase
              Suitable for Manual motor starter

              General Information
              • Extended Product Type:SK1-02
              • Product ID:1SAM201903R1003
              • Catalog Description:SK1-02 Signal Contact
              • Long Description:SK1-02 Signal contact
              Dimensions
              • Product Net Width:9 mm
              • Product Net Height:90 mm
              • Product Net Depth:78.5 mm
              • Product Net Weight:0.035 kg
              Specification
              • Rated Operational Voltage:690 V AC
                600 V DC
                Main Circuit 690 V
              • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                (24 V) 6 A
                (380 / 400 V) 3 A
                (690 V) 1 A
              • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                (24 V) 2 A
                (250 V) 0.27 A
                (440 V) 0 A
                (600 V) 0 A
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                Flexible 1/2x 0.75 ... 1.5 mm²
                Rigid 1/2x 1 ... 1.5 mm²
              • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
              • Wire Stripping Length:Auxiliary Circuit 8 mm
              • Recommended Screw Driver:M3
                Pozidriv 2
              • Number of Auxiliary Contacts NO:0
              • Number of Auxiliary Contacts NC:2
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 60947-1
                UL 60947-4-1
              • Product Name:Signal Contact
              • Suitable For:MS116
                MS132
              • Suitable for Product Class:Manual Motor Starter
              Environmental
              • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
                Request
                Callback


                Additional Information:

                • Item Code: 1SAM201903R1003
                • Pay Mode Terms: T/T (Bank Transfer)
                Send Business Enquiry

                ABB TA25DU 0.16M (Thermal Overload Relays)

                ABB TA25DU 0.16M (Thermal Overload Relays)
                • ABB TA25DU 0.16M (Thermal Overload Relays)
                Get Best Quote
                Approx. Price: Rs 887 / UnitGet Latest Price

                Product Details:

                Minimum Order Quantity1 Unit
                Voltage (V)415v
                Voltage TypeAC
                Current (Amps)0.1-0.16Amps
                ApplicationDirect mounting on contactors

                General Information
                • Extended Product Type:TA25DU-0.16M
                • Product ID:1SAZ211201R2005
                • Catalog Description:TA25DU-0.16M Thermal Overload Relays
                • Long Description:TA25DU-0.16M (0.1-0.16A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                Dimensions
                • Product Net Width:44 mm
                • Product Net Height:80 mm
                • Product Net Depth:94 mm
                • Product Net Weight:0.15 kg
                Specification
                • Setting Range:0.10 ... 0.16 A
                • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                  Main Circuit 690 V AC
                • Rated Operational Current (Ie):0.16 A
                • Rated Operational Current AC-3 (Ie):0.16 A
                • Rated Frequency (f):Auxiliary Circuit 50 Hz
                  Auxiliary Circuit 60 Hz
                  Auxiliary Circuit DC
                  Main Circuit 60 Hz
                  Main Circuit 50 Hz
                  Main Circuit DC
                • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                  Main Circuit 6 kV
                • Rated Insulation Voltage (Ui):690 V
                • Number of Poles:3
                • Number of Auxiliary Contacts NC:1
                • Number of Auxiliary Contacts NO:1
                • Number of Protected Poles:3
                • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                  Auxiliary Circuit NO 5 A
                • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                  (120 V) NO 1.500 A
                  (240 V) NC 3.000 A
                  (240 V) NO 1.500 A
                  (400 V) NC 1.900 A
                  (400 V) NO 1.000 A
                  (440 V) NC 1.000 A
                  (440 V) NO 1.000 A
                  (500 V) NC 1.000 A
                  (500 V) NO 1.000 A
                • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                  (125 V) NO 0.250 A
                  (24 V) NC 1.250 A
                  (24 V) NO 1.250 A
                  (250 V) NC 0.120 A
                  (250 V) NO 0.040 A
                  (60 V) NC 0.250 A
                  (60 V) NO 0.250 A
                • Degree of Protection:Housing IP20
                  Main Circuit Terminals IP10
                • Pollution Degree:3
                • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                  Rigid 1/2x 0.75 ... 4 mm²
                • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                  Flexible with Ferrule 2x 0.75 ... 4 mm²
                  Flexible 1x 0.75 ... 4 mm²
                  Flexible 2x 0.75 ... 4 mm²
                  Rigid 1x 0.75 ... 4 mm²
                  Rigid 2x 0.75 ... 4 mm²
                • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                  Main Circuit 1.5 ... 1.9 N·m
                • Wire Stripping Length:Auxiliary Circuit 9 mm
                  Main Circuit 12 mm
                • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                  Main Circuit Pozidriv 2
                • Mounting Position:Position 1 to 4
                • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                • Suitable For:AX09
                  AX12
                  AX18
                  AX25
                  AX32
                  AX40
                • Standards:IEC/EN 60947-1
                  IEC/EN 60947-4-1
                  IEC/EN 60947-5-1
                  UL 508
                  CSA 22.2 No. 14
                Environmental
                • Ambient Air Temperature:Operation -25 ... +55 °C
                  Operation Compensated -25 ... +55 °C
                  Storage -40 ... +70 °C
                • Ambient Air Temperature Compensation:Yes
                • Maximum Operating Altitude Permissible:2000 m
                • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                • RoHS Status:Following EU Directive 2011/65/EC
                  Request
                  Callback


                  Additional Information:

                  • Item Code: 1SAZ211201R2005
                  • Pay Mode Terms: T/T (Bank Transfer)
                  Send Business Enquiry

                  ABB TA25DU 0.25M (Thermal Overload Relay)

                  ABB TA25DU 0.25M (Thermal Overload Relay)
                  • ABB TA25DU 0.25M (Thermal Overload Relay)
                  Get Best Quote
                  Approx. Price: Rs 887 / UnitGet Latest Price

                  Product Details:

                  Minimum Order Quantity1 Unit
                  Voltage (V)415V
                  Voltage TypeAC
                  Current (Amps)0.16-0.25Amps
                  Applicationdirect mounting on contactors

                  General Information
                  • Extended Product Type:TA25DU-0.25M
                  • Product ID:1SAZ211201R2009
                  • Catalog Description:TA25DU-0.25M Thermal Overload Relays
                  • Long Description:TA25DU-0.25M (0.16-0.25A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                  Dimensions
                  • Product Net Width:44 mm
                  • Product Net Height:80 mm
                  • Product Net Depth:94 mm
                  • Product Net Weight:0.15 kg
                  Technical
                  • Setting Range:0.16 ... 0.25 A
                  • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                    Main Circuit 690 V AC
                  • Rated Operational Current (Ie):0.25 A
                  • Rated Operational Current AC-3 (Ie):0.25 A
                  • Rated Frequency (f):Auxiliary Circuit 50 Hz
                    Auxiliary Circuit 60 Hz
                    Auxiliary Circuit DC
                    Main Circuit 60 Hz
                    Main Circuit 50 Hz
                    Main Circuit DC
                  • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                    Main Circuit 6 kV
                  • Rated Insulation Voltage (Ui):690 V
                  • Number of Poles:3
                  • Number of Auxiliary Contacts NC:1
                  • Number of Auxiliary Contacts NO:1
                  • Number of Protected Poles:3
                  • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                    Auxiliary Circuit NO 5 A
                  • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                    (120 V) NO 1.500 A
                    (240 V) NC 3.000 A
                    (240 V) NO 1.500 A
                    (400 V) NC 1.900 A
                    (400 V) NO 1.000 A
                    (440 V) NC 1.000 A
                    (440 V) NO 1.000 A
                    (500 V) NC 1.000 A
                    (500 V) NO 1.000 A
                  • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                    (125 V) NO 0.250 A
                    (24 V) NC 1.250 A
                    (24 V) NO 1.250 A
                    (250 V) NC 0.120 A
                    (250 V) NO 0.040 A
                    (60 V) NC 0.250 A
                    (60 V) NO 0.250 A
                  • Degree of Protection:Housing IP20
                    Main Circuit Terminals IP10
                  • Pollution Degree:3
                  • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                    Rigid 1/2x 0.75 ... 4 mm²
                  • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                    Flexible with Ferrule 2x 0.75 ... 4 mm²
                    Flexible 1x 0.75 ... 4 mm²
                    Flexible 2x 0.75 ... 4 mm²
                    Rigid 1x 0.75 ... 4 mm²
                    Rigid 2x 0.75 ... 4 mm²
                  • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                    Main Circuit 1.5 ... 1.9 N·m
                  • Wire Stripping Length:Auxiliary Circuit 9 mm
                    Main Circuit 12 mm
                  • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                    Main Circuit Pozidriv 2
                  • Mounting Position:Position 1 to 4
                  • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                  • Suitable For:AX09
                    AX12
                    AX18
                    AX25
                    AX32
                    AX40
                  • Standards:IEC/EN 60947-1
                    IEC/EN 60947-4-1
                    IEC/EN 60947-5-1
                    UL 508
                    CSA 22.2 No. 14
                  Environmental
                  • Ambient Air Temperature:Operation -25 ... +55 °C
                    Operation Compensated -25 ... +55 °C
                    Storage -40 ... +70 °C
                  • Ambient Air Temperature Compensation:Yes
                  • Maximum Operating Altitude Permissible:2000 m
                  • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                  • RoHS Status:Following EU Directive 2011/65/EC
                    Request
                    Callback


                    Additional Information:

                    • Item Code: 1SAZ211201R2009
                    • Pay Mode Terms: T/T (Bank Transfer)
                    Send Business Enquiry

                    ABB TA25DU 0.4M (Thermal Overload Relay)

                    ABB TA25DU 0.4M (Thermal Overload Relay)
                    • ABB TA25DU 0.4M (Thermal Overload Relay)
                    Get Best Quote
                    Approx. Price: Rs 887 / UnitGet Latest Price

                    Product Details:

                    Minimum Order Quantity1 Unit
                    Voltage (V)415V
                    Voltage TypeAC
                    Current (Amps)0.25-0.4Amps
                    ApplicationDirect mounting on contactors

                    General Information
                    • Extended Product Type:TA25DU-0.4M
                    • Product ID:1SAZ211201R2013
                    • Catalog Description:TA25DU-0.4M Thermal Overload Relays
                    • Long Description:TA25DU-0.4M (0.25-0.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                    Dimensions
                    • Product Net Width:44 mm
                    • Product Net Height:80 mm
                    • Product Net Depth:94 mm
                    • Product Net Weight:0.15 kg
                    Specification
                    • Setting Range:0.25 ... 0.40 A
                    • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                      Main Circuit 690 V AC
                    • Rated Operational Current (Ie):0.4 A
                    • Rated Operational Current AC-3 (Ie):0.4 A
                    • Rated Frequency (f):Auxiliary Circuit 50 Hz
                      Auxiliary Circuit 60 Hz
                      Auxiliary Circuit DC
                      Main Circuit 60 Hz
                      Main Circuit 50 Hz
                      Main Circuit DC
                    • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                      Main Circuit 6 kV
                    • Rated Insulation Voltage (Ui):690 V
                    • Number of Poles:3
                    • Number of Auxiliary Contacts NC:1
                    • Number of Auxiliary Contacts NO:1
                    • Number of Protected Poles:3
                    • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                      Auxiliary Circuit NO 5 A
                    • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                      (120 V) NO 1.500 A
                      (240 V) NC 3.000 A
                      (240 V) NO 1.500 A
                      (400 V) NC 1.900 A
                      (400 V) NO 1.000 A
                      (440 V) NC 1.000 A
                      (440 V) NO 1.000 A
                      (500 V) NC 1.000 A
                      (500 V) NO 1.000 A
                    • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                      (125 V) NO 0.250 A
                      (24 V) NC 1.250 A
                      (24 V) NO 1.250 A
                      (250 V) NC 0.120 A
                      (250 V) NO 0.040 A
                      (60 V) NC 0.250 A
                      (60 V) NO 0.250 A
                    • Degree of Protection:Housing IP20
                      Main Circuit Terminals IP10
                    • Pollution Degree:3
                    • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                      Rigid 1/2x 0.75 ... 4 mm²
                    • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                      Flexible with Ferrule 2x 0.75 ... 4 mm²
                      Flexible 1x 0.75 ... 4 mm²
                      Flexible 2x 0.75 ... 4 mm²
                      Rigid 1x 0.75 ... 4 mm²
                      Rigid 2x 0.75 ... 4 mm²
                    • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                      Main Circuit 1.5 ... 1.9 N·m
                    • Wire Stripping Length:Auxiliary Circuit 9 mm
                      Main Circuit 12 mm
                    • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                      Main Circuit Pozidriv 2
                    • Mounting Position:Position 1 to 4
                    • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                    • Suitable For:AX09
                      AX12
                      AX18
                      AX25
                      AX32
                      AX40
                    • Standards:IEC/EN 60947-1
                      IEC/EN 60947-4-1
                      IEC/EN 60947-5-1
                      UL 508
                      CSA 22.2 No. 14
                    Environmental
                    • Ambient Air Temperature:Operation -25 ... +55 °C
                      Operation Compensated -25 ... +55 °C
                      Storage -40 ... +70 °C
                    • Ambient Air Temperature Compensation:Yes
                    • Maximum Operating Altitude Permissible:2000 m
                    • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                    • RoHS Status:Following EU Directive 2011/65/EC
                      Request
                      Callback


                      Additional Information:

                      • Item Code: 1SAZ211201R2013
                      • Pay Mode Terms: T/T (Bank Transfer)
                      Send Business Enquiry

                      ABB TA25DU 0.63M( Thermal Overload Relay)

                      ABB TA25DU 0.63M( Thermal Overload Relay)
                      • ABB TA25DU 0.63M( Thermal Overload Relay)
                      Get Best Quote
                      Approx. Price: Rs 887 / UnitGet Latest Price

                      Product Details:

                      Minimum Order Quantity1 Unit
                      Voltage (V)415v
                      Voltage TypeAC
                      Current (Amps)0.4-0.63Amps
                      Applicationdirect mounting on contactors

                      General Information
                      • Extended Product Type:TA25DU-0.63M
                      • Product ID:1SAZ211201R2017
                      • Catalog Description:TA25DU-0.63M Thermal Overload Relays
                      • Long Description:TA25DU-0.63M (0.4-0.63A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                      Dimensions
                      • Product Net Width:44 mm
                      • Product Net Height:80 mm
                      • Product Net Depth:94 mm
                      • Product Net Weight:0.15 kg
                      Specification
                      • Setting Range:0.40 ... 0.63 A
                      • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                        Main Circuit 690 V AC
                      • Rated Operational Current (Ie):0.63 A
                      • Rated Operational Current AC-3 (Ie):0.63 A
                      • Rated Frequency (f):Auxiliary Circuit 50 Hz
                        Auxiliary Circuit 60 Hz
                        Auxiliary Circuit DC
                        Main Circuit 60 Hz
                        Main Circuit 50 Hz
                        Main Circuit DC
                      • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                        Main Circuit 6 kV
                      • Rated Insulation Voltage (Ui):690 V
                      • Number of Poles:3
                      • Number of Auxiliary Contacts NC:1
                      • Number of Auxiliary Contacts NO:1
                      • Number of Protected Poles:3
                      • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                        Auxiliary Circuit NO 5 A
                      • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                        (120 V) NO 1.500 A
                        (240 V) NC 3.000 A
                        (240 V) NO 1.500 A
                        (400 V) NC 1.900 A
                        (400 V) NO 1.000 A
                        (440 V) NC 1.000 A
                        (440 V) NO 1.000 A
                        (500 V) NC 1.000 A
                        (500 V) NO 1.000 A
                      • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                        (125 V) NO 0.250 A
                        (24 V) NC 1.250 A
                        (24 V) NO 1.250 A
                        (250 V) NC 0.120 A
                        (250 V) NO 0.040 A
                        (60 V) NC 0.250 A
                        (60 V) NO 0.250 A
                      • Degree of Protection:Housing IP20
                        Main Circuit Terminals IP10
                      • Pollution Degree:3
                      • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                        Rigid 1/2x 0.75 ... 4 mm²
                      • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                        Flexible with Ferrule 2x 0.75 ... 4 mm²
                        Flexible 1x 0.75 ... 4 mm²
                        Flexible 2x 0.75 ... 4 mm²
                        Rigid 1x 0.75 ... 4 mm²
                        Rigid 2x 0.75 ... 4 mm²
                      • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                        Main Circuit 1.5 ... 1.9 N·m
                      • Wire Stripping Length:Auxiliary Circuit 9 mm
                        Main Circuit 12 mm
                      • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                        Main Circuit Pozidriv 2
                      • Mounting Position:Position 1 to 4
                      • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                      • Suitable For:AX09
                        AX12
                        AX18
                        AX25
                        AX32
                        AX40
                      • Standards:IEC/EN 60947-1
                        IEC/EN 60947-4-1
                        IEC/EN 60947-5-1
                        UL 508
                        CSA 22.2 No. 14
                      Environmental
                      • Ambient Air Temperature:Operation -25 ... +55 °C
                        Operation Compensated -25 ... +55 °C
                        Storage -40 ... +70 °C
                      • Ambient Air Temperature Compensation:Yes
                      • Maximum Operating Altitude Permissible:2000 m
                      • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                      • RoHS Status:Following EU Directive 2011/65/EC
                        Request
                        Callback


                        Additional Information:

                        • Item Code: 1SAZ211201R2017
                        • Pay Mode Terms: T/T (Bank Transfer)
                        Send Business Enquiry

                        ABB TA25DU 1.0M (Thermal Overload Relay)

                        ABB TA25DU 1.0M  (Thermal Overload Relay)
                        • ABB TA25DU 1.0M  (Thermal Overload Relay)
                        Get Best Quote
                        Approx. Price: Rs 887 / UnitGet Latest Price

                        Product Details:

                        Minimum Order Quantity1 Unit
                        Voltage (V)415V
                        Voltage TypeAC
                        Current (Amps)0.63-1.0Amps
                        ApplicationDirect mounting on contactors

                        General Information
                        • Extended Product Type:TA25DU-1.0M
                        • Product ID:1SAZ211201R2021
                        • Catalog Description:TA25DU-1.0M Thermal Overload Relays
                        • Long Description:TA25DU-1.0M (0.63-1.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                        Dimensions
                        • Product Net Width:44 mm
                        • Product Net Height:80 mm
                        • Product Net Depth:94 mm
                        • Product Net Weight:0.15 kg
                        Specification
                        • Setting Range:0.63 ... 1.00 A
                        • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                          Main Circuit 690 V AC
                        • Rated Operational Current (Ie):1 A
                        • Rated Operational Current AC-3 (Ie):1 A
                        • Rated Frequency (f):Auxiliary Circuit 50 Hz
                          Auxiliary Circuit 60 Hz
                          Auxiliary Circuit DC
                          Main Circuit 60 Hz
                          Main Circuit 50 Hz
                          Main Circuit DC
                        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                          Main Circuit 6 kV
                        • Rated Insulation Voltage (Ui):690 V
                        • Number of Poles:3
                        • Number of Auxiliary Contacts NC:1
                        • Number of Auxiliary Contacts NO:1
                        • Number of Protected Poles:3
                        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                          Auxiliary Circuit NO 5 A
                        • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                          (120 V) NO 1.500 A
                          (240 V) NC 3.000 A
                          (240 V) NO 1.500 A
                          (400 V) NC 1.900 A
                          (400 V) NO 1.000 A
                          (440 V) NC 1.000 A
                          (440 V) NO 1.000 A
                          (500 V) NC 1.000 A
                          (500 V) NO 1.000 A
                        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                          (125 V) NO 0.250 A
                          (24 V) NC 1.250 A
                          (24 V) NO 1.250 A
                          (250 V) NC 0.120 A
                          (250 V) NO 0.040 A
                          (60 V) NC 0.250 A
                          (60 V) NO 0.250 A
                        • Degree of Protection:Housing IP20
                          Main Circuit Terminals IP10
                        • Pollution Degree:3
                        • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                          Rigid 1/2x 0.75 ... 4 mm²
                        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                          Flexible with Ferrule 2x 0.75 ... 4 mm²
                          Flexible 1x 0.75 ... 4 mm²
                          Flexible 2x 0.75 ... 4 mm²
                          Rigid 1x 0.75 ... 4 mm²
                          Rigid 2x 0.75 ... 4 mm²
                        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                          Main Circuit 1.5 ... 1.9 N·m
                        • Wire Stripping Length:Auxiliary Circuit 9 mm
                          Main Circuit 12 mm
                        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                          Main Circuit Pozidriv 2
                        • Mounting Position:Position 1 to 4
                        • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                        • Suitable For:AX09
                          AX12
                          AX18
                          AX25
                          AX32
                          AX40
                        • Standards:IEC/EN 60947-1
                          IEC/EN 60947-4-1
                          IEC/EN 60947-5-1
                          UL 508
                          CSA 22.2 No. 14
                        Environmental
                        • Ambient Air Temperature:Operation -25 ... +55 °C
                          Operation Compensated -25 ... +55 °C
                          Storage -40 ... +70 °C
                        • Ambient Air Temperature Compensation:Yes
                        • Maximum Operating Altitude Permissible:2000 m
                        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                        • RoHS Status:Following EU Directive 2011/65/EC
                          Request
                          Callback


                          Additional Information:

                          • Item Code: 1SAZ211201R2021
                          • Pay Mode Terms: T/T (Bank Transfer)
                          Send Business Enquiry

                          ABB TA25DU 19M( Thermal Overload Relay)

                          ABB TA25DU 19M( Thermal Overload Relay)
                          • ABB TA25DU 19M( Thermal Overload Relay)
                          Get Best Quote
                          Approx. Price: Rs 1,098 / UnitGet Latest Price

                          Product Details:

                          Minimum Order Quantity1 Unit
                          Voltage (V)415V
                          Voltage TypeAC
                          Current (Amps)13.0-19.0Amps
                          ApplicationProtect from Phase Loss and Overload

                          General Information
                          • Extended Product Type:TA25DU-19M
                          • Product ID:1SAZ211201R2047
                          • Catalog Description:TA25DU-19M Thermal Overload Relays
                          • Long Description:TA25DU-19M (13.0-19.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                          Dimensions
                          • Product Net Width:44 mm
                          • Product Net Height:80 mm
                          • Product Net Depth:94 mm
                          • Product Net Weight:0.17 kg
                          Specification
                          • Setting Range:13.0 ... 19.0 A
                          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                            Main Circuit 690 V AC
                          • Rated Operational Current (Ie):19 A
                          • Rated Operational Current AC-3 (Ie):19 A
                          • Rated Frequency (f):Auxiliary Circuit 50 Hz
                            Auxiliary Circuit 60 Hz
                            Auxiliary Circuit DC
                            Main Circuit 60 Hz
                            Main Circuit 50 Hz
                            Main Circuit DC
                          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                            Main Circuit 6 kV
                          • Rated Insulation Voltage (Ui):690 V
                          • Number of Poles:3
                          • Number of Auxiliary Contacts NC:1
                          • Number of Auxiliary Contacts NO:1
                          • Number of Protected Poles:3
                          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                            Auxiliary Circuit NO 5 A
                          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                            (120 V) NO 1.500 A
                            (240 V) NC 3.000 A
                            (240 V) NO 1.500 A
                            (400 V) NC 1.900 A
                            (400 V) NO 1.000 A
                            (440 V) NC 1.000 A
                            (440 V) NO 1.000 A
                            (500 V) NC 1.000 A
                            (500 V) NO 1.000 A
                          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                            (125 V) NO 0.250 A
                            (24 V) NC 1.250 A
                            (24 V) NO 1.250 A
                            (250 V) NC 0.120 A
                            (250 V) NO 0.040 A
                            (60 V) NC 0.250 A
                            (60 V) NO 0.250 A
                          • Degree of Protection:Housing IP20
                            Main Circuit Terminals IP10
                          • Pollution Degree:3
                          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                            Rigid 1/2x 0.75 ... 4 mm²
                          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                            Flexible with Ferrule 2x 0.75 ... 4 mm²
                            Flexible 1x 0.75 ... 4 mm²
                            Flexible 2x 0.75 ... 4 mm²
                            Rigid 1x 0.75 ... 4 mm²
                            Rigid 2x 0.75 ... 4 mm²
                          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                            Main Circuit 1.5 ... 1.9 N·m
                          • Wire Stripping Length:Auxiliary Circuit 9 mm
                            Main Circuit 12 mm
                          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                            Main Circuit Pozidriv 2
                          • Mounting Position:Position 1 to 4
                          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.3 W
                          • Suitable For:AX09
                            AX12
                            AX18
                            AX25
                            AX32
                            AX40
                          • Standards:IEC/EN 60947-1
                            IEC/EN 60947-4-1
                            IEC/EN 60947-5-1
                            UL 508
                            CSA 22.2 No. 14
                          Environmental
                          • Ambient Air Temperature:Operation -25 ... +55 °C
                            Operation Compensated -25 ... +55 °C
                            Storage -40 ... +70 °C
                          • Ambient Air Temperature Compensation:Yes
                          • Maximum Operating Altitude Permissible:2000 m
                          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                          • RoHS Status:Following EU Directive 2011/65/EC
                          Request
                          Callback


                          Additional Information:

                          • Item Code: 1SAZ211201R2047
                          • Pay Mode Terms: T/T (Bank Transfer)
                          Send Business Enquiry

                          ABB HKF1-10 (Auxiliary Contact- Front)

                          ABB HKF1-10 (Auxiliary Contact- Front)
                          • ABB HKF1-10 (Auxiliary Contact- Front)
                          Get Best Quote
                          Approx. Price: Rs 247 / UnitGet Latest Price

                          Product Details:

                          Minimum Order Quantity1 Unit
                          BrandABB
                          Starter TypeSuitable for manual motor starter
                          PhaseThree Phase

                          General Information
                          • Extended Product Type:HKF1-10
                          • Product ID:1SAM201901R1003
                          • Catalog Description:HKF1-10 Auxiliary Contact
                          • Long Description:HKF1-10 Aux.-contact for front mounting
                          Dimensions
                          • Product Net Width:45 mm
                          • Product Net Height:12.5 mm
                          • Product Net Depth:26.5 mm
                          • Product Net Weight:0.013 kg
                          Specification
                          • Rated Operational Voltage:250 V
                          • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                            (24 V) 6 A
                            (380 / 400 V) 3 A
                            (690 V) 1 A
                          • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                            (24 V) 2 A
                            (250 V) 0.27 A
                          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                          • Rated Insulation Voltage (Ui):250 V
                          • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                            Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                            Flexible 1/2x 0.75 ... 1.5 mm²
                            Rigid 1/2x 1.0 ... 2.5 mm²
                          • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                          • Wire Stripping Length:Auxiliary Circuit 8 mm
                          • Recommended Screw Driver:M3
                            Pozidriv 2
                          • Number of Auxiliary Contacts NO:1
                          • Product Name:Auxiliary Contact
                          • Suitable For:MS165
                            MO165
                            MS132
                            MO132
                            MS116
                          Environmental
                          • Ambient Air Temperature:Operation -20 ... +55 °C
                            Storage -50 ... +80 °C
                            Request
                            Callback


                            Additional Information:

                            • Item Code: 1SAM201901R1003
                            • Pay Mode Terms: T/T (Bank Transfer)
                            Send Business Enquiry

                            ABB HK1-20 ( Auxiliary Contacts- Right)

                            ABB HK1-20 ( Auxiliary Contacts- Right)
                            • ABB HK1-20 ( Auxiliary Contacts- Right)
                            Get Best Quote
                            Approx. Price: Rs 521 / UnitGet Latest Price

                            Product Details:

                            Minimum Order Quantity1 Unit
                            BrandABB
                            Starter Typesuitable for manual motor
                            PhaseThree Phase

                            General Information
                            • Extended Product Type:HK1-20
                            • Product ID:1SAM201902R1002
                            • Catalog Description:HK1-20 Auxiliary Contact
                            • Long Description:HK1-20 Aux.-contact
                            Dimensions
                            • Product Net Width:9 mm
                            • Product Net Height:90 mm
                            • Product Net Depth:78.5 mm
                            • Product Net Weight:0.035 kg
                            Specification
                            • Rated Operational Voltage:690 V AC
                              600 V DC
                              Main Circuit 690 V
                            • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                              (24 V) 6 A
                              (380 / 400 V) 3 A
                              (690 V) 1 A
                            • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                              (24 V) 2 A
                              (250 V) 0.27 A
                              (440 V) 0 A
                              (600 V) 0 A
                            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                            • Rated Insulation Voltage (Ui):690 V
                            • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                              Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                              Flexible 1/2x 0.75 ... 1.5 mm²
                              Rigid 1/2x 1 ... 1.5 mm²
                            • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                            • Wire Stripping Length:Auxiliary Circuit 8 mm
                            • Recommended Screw Driver:M3
                              Pozidriv 2
                            • Number of Auxiliary Contacts NO:2
                            • Number of Auxiliary Contacts NC:0
                            • Standards:IEC/EN 60947-1
                              IEC/EN 60947-4-1
                              IEC/EN 60947-5-1
                              UL 60947-1
                              UL 60947-4-1
                            • Product Name:Auxiliary Contact
                            • Suitable For:MS116
                              MS132
                            • Suitable for Product Class:Manual Motor Starter
                            Environmental
                            • Ambient Air Temperature:Operation -20 ... +55 °C
                              Storage -50 ... +80 °C
                            • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
                              Request
                              Callback


                              Additional Information:

                              • Item Code: 1SAM201902R1002
                              • Pay Mode Terms: T/T (Bank Transfer)
                              Send Business Enquiry

                              ABB SK1-20 ( Signaling Contacts- Right)

                              ABB SK1-20 ( Signaling Contacts- Right)
                              • ABB SK1-20 ( Signaling Contacts- Right)
                              Get Best Quote
                              Approx. Price: Rs 690 / UnitGet Latest Price

                              Product Details:

                              Minimum Order Quantity1 Unit
                              BrandABB
                              Starter Typesuitable for manual motor starter
                              PhaseThree Phase

                              General Information
                              • Extended Product Type:SK1-20
                              • Product ID:1SAM201903R1002
                              • Catalog Description:SK1-20 Signal Contact
                              • Long Description:SK1-20 Signal contact
                              Dimensions
                              • Product Net Width:9 mm
                              • Product Net Height:90 mm
                              • Product Net Depth:78.5 mm
                              • Product Net Weight:0.035 kg
                              Specification
                              • Rated Operational Voltage:690 V AC
                                600 V DC
                                Main Circuit 690 V
                              • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                                (24 V) 6 A
                                (380 / 400 V) 3 A
                                (690 V) 1 A
                              • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                                (24 V) 2 A
                                (250 V) 0.27 A
                                (440 V) 0 A
                                (600 V) 0 A
                              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                              • Rated Insulation Voltage (Ui):690 V
                              • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                                Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                                Flexible 1/2x 0.75 ... 1.5 mm²
                                Rigid 1/2x 1 ... 1.5 mm²
                              • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                              • Wire Stripping Length:Auxiliary Circuit 8 mm
                              • Recommended Screw Driver:M3
                                Pozidriv 2
                              • Number of Auxiliary Contacts NO:2
                              • Number of Auxiliary Contacts NC:0
                              • Standards:IEC/EN 60947-1
                                IEC/EN 60947-4-1
                                IEC/EN 60947-5-1
                                UL 60947-1
                                UL 60947-4-1
                              • Product Name:Signal Contact
                              • Suitable For:MS116
                                MS132
                              • Suitable for Product Class:Manual Motor Starter
                              Environmental
                              • Ambient Air Temperature:Operation -20 ... +55 °C
                                Storage -50 ... +80 °C
                              • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment
                                Request
                                Callback


                                Additional Information:

                                • Item Code: 1SAM201903R1002
                                • Pay Mode Terms: T/T (Bank Transfer)
                                Send Business Enquiry

                                ABB CK1-02( Signaling Contacts Right)

                                ABB CK1-02( Signaling Contacts Right)
                                • ABB CK1-02( Signaling Contacts Right)
                                Get Best Quote
                                Approx. Price: Rs 979 / UnitGet Latest Price

                                Product Details:

                                Minimum Order Quantity1 Unit
                                Starter Typemanual motor starter
                                Coil Voltage 480 V
                                Phase Three Phase

                                General Information
                                • Extended Product Type:CK1-02
                                • Product ID:1SAM301901R1003
                                • Catalog Description:CK1-02 Short Circuit Signaling Contact
                                • Long Description:CK1-02 Short-Circuit Signal Contact 2 NC
                                Dimensions
                                • Product Net Width:9 mm
                                • Product Net Height:90 mm
                                • Product Net Depth:78 mm
                                • Product Net Weight:0.035 kg
                                Specification
                                • Rated Operational Voltage:690 V AC
                                  600 V DC
                                  Main Circuit 690 V
                                • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                                  (24 V) 6 A
                                  (380 / 400 V) 3 A
                                  (690 V) 1 A
                                • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                                  (24 V) 2 A
                                  (250 V) 0.27 A
                                  (440 V) 0 A
                                  (600 V) 0 A
                                • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                                • Rated Insulation Voltage (Ui):690 V
                                • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                                  Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                                  Flexible 1/2x 0.75 ... 1.5 mm²
                                  Rigid 1/2x 1 ... 1.5 mm²
                                • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                                • Wire Stripping Length:Auxiliary Circuit 8 mm
                                • Recommended Screw Driver:M3
                                  Pozidriv 2
                                • Number of Auxiliary Contacts NO:0
                                • Number of Auxiliary Contacts NC:2
                                • Standards:IEC/EN 60947-1
                                  IEC/EN 60947-2
                                  IEC/EN 60947-4-1
                                  IEC/EN 60947-5-1
                                  UL 508
                                  CSA 22.2 No. 14
                                • Product Name:Short Circuit Signaling Contact
                                • Suitable For:MS132
                                • Suitable for Product Class:Manual Motor Starter
                                Environmental
                                • RoHS Status:Following EU Directive 2011/65/EC
                                  Request
                                  Callback


                                  Additional Information:

                                  • Item Code: 1SAM301901R1003
                                  • Pay Mode Terms: T/T (Bank Transfer)
                                  Send Business Enquiry

                                  ABB MS495 (Manual Motor Starter/ Circuit Breaker)

                                  ABB MS495 (Manual Motor Starter/ Circuit Breaker)
                                  • ABB MS495 (Manual Motor Starter/ Circuit Breaker)
                                  Ask For Price
                                  Product Price :Get Latest Price

                                  Product Details:

                                  Minimum Order Quantity1 Number
                                  Poles Number3 Pole
                                  Power415V
                                  Rated current45-63Amps
                                  Rated short circuit breaking capacity50KA

                                  General Information
                                  • Extended Product Type:MS495
                                  • Catalog Description:MS495 Manual Motor Starter
                                  • Long Description:The MS495 manual motor starter is a 70 mm width devices with a rated operational current of Ie = 63.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases and shunt trips are available as accessory.
                                  Dimensions
                                  • Product Net Width:70 mm
                                  • Product Net Height:165 mm
                                  • Product Net Depth:174 mm
                                  • Product Net Weight:2.247 kg
                                  Specification
                                  • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA
                                    (400 V AC) 25 kA
                                    (440 V AC) 20 kA
                                    (500 V AC) 6 kA
                                    (690 V AC) 3 kA
                                  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
                                    (400 V AC) 50 kA
                                    (440 V AC) 50 kA
                                    (500 V AC) 12 kA
                                    (690 V AC) 6 kA
                                  • Rated Instantaneous Short-Circuit Current Setting (Ii):819 A
                                  • Setting Range:45 ... 63 A
                                  • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 30 kW
                                  • Rated Operational Voltage:Main Circuit 690 V AC
                                    Main Circuit 450 V DC
                                  • Rated Operational Current (Ie):63 A
                                  • Rated Operational Current AC-3 (Ie):63 A
                                  • Rated Frequency (f):Main Circuit 50 Hz
                                    Main Circuit 60 Hz
                                  • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
                                  • Rated Insulation Voltage (Ui):690 V
                                  • Power Loss:at Rated Operating Conditions per Pole 2.9 … 5.6 W
                                  • Number of Poles:3
                                  • Conventional Free-air Thermal Current (Ith):Main Circuit 63 A
                                  • Degree of Protection:Housing IP20
                                    Main Circuit Terminals IP00
                                  • Pollution Degree:3
                                  • Electrical Durability:25000 cycle
                                  • Mechanical Durability:50000 cycle
                                  • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 50 mm²
                                    Flexible with Ferrule 2x 2.5 ... 35 mm²
                                    Solid 1/2x 2.5 ... 16 mm²
                                    Stranded 1x 10 ... 70 mm²
                                    Stranded 2x 10 ... 50 mm²
                                  • Tightening Torque:Main Circuit 4 ... 6 N·m
                                  • Wire Stripping Length:Main Circuit 17 mm
                                  • Recommended Screw Driver:Hexagon 4
                                  • Mounting Position:Position 1 to 6
                                  • Actuator Type:Rotary Handle
                                  • Contact Position Indication:ON / OFF / TRIP
                                  • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
                                    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
                                  • Standards:IEC/EN 60947-1
                                    IEC/EN 60947-2
                                    IEC/EN 60947-4-1
                                    UL 508
                                    CSA 22.2 No. 14
                                  Environmental
                                  • Ambient Air Temperature:Operation -20 ... +70 °C
                                    Operation Compensated -20 ... +60 °C
                                    Storage -50 ... +80 °C
                                  • Ambient Air Temperature Compensation:Yes
                                  • Maximum Operating Altitude Permissible:2000 m
                                  • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 25g
                                  • RoHS Status:Following EU Directive 2011/65/EC
                                    Request
                                    Callback


                                    Additional Information:

                                    • Pay Mode Terms: T/T (Bank Transfer)
                                    Send Business Enquiry

                                    ABB MS497( Manual Motor Starter / Circuit Breaker)

                                    ABB MS497( Manual Motor Starter / Circuit Breaker)
                                    • ABB MS497( Manual Motor Starter / Circuit Breaker)
                                    Ask For Price
                                    Product Price :Get Latest Price

                                    Product Details:

                                    Minimum Order Quantity1 Number
                                    Poles Number3 Pole
                                    Power415V
                                    Rated current22-100Amps
                                    Rated short circuit breaking capacity100kA

                                    General Information
                                    • Extended Product Type:MS497
                                    • Catalog Description:MS497 Manual Motor Starter
                                    • Long Description:The MS497 manual motor starter is a 70 mm width devices with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases and shunt trips are available as accessory.
                                    Dimensions
                                    • Product Net Width:70 mm
                                    • Product Net Height:165 mm
                                    • Product Net Depth:174 mm
                                    • Product Net Weight:2.222 kg
                                    Specification
                                    • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA
                                      (400 V AC) 50 kA
                                      (440 V AC) 50 kA
                                      (500 V AC) 11 kA
                                      (690 V AC) 6 kA
                                    • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
                                      (400 V AC) 100 kA
                                      (440 V AC) 100 kA
                                      (500 V AC) 22 kA
                                      (690 V AC) 12 kA
                                    • Rated Instantaneous Short-Circuit Current Setting (Ii):416 A
                                    • Setting Range:22 ... 32 A
                                    • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 15 kW
                                    • Rated Operational Voltage:Main Circuit 690 V AC
                                      Main Circuit 450 V DC
                                    • Rated Operational Current (Ie):32 A
                                    • Rated Operational Current AC-3 (Ie):32 A
                                    • Rated Frequency (f):Main Circuit 50 Hz
                                      Main Circuit 60 Hz
                                    • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
                                    • Rated Insulation Voltage (Ui):690 V
                                    • Power Loss:at Rated Operating Conditions per Pole 3.2 … 6.7 W
                                    • Number of Poles:3
                                    • Conventional Free-air Thermal Current (Ith):Main Circuit 32 A
                                    • Degree of Protection:Housing IP20
                                      Main Circuit Terminals IP00
                                    • Pollution Degree:3
                                    • Electrical Durability:25000 cycle
                                    • Mechanical Durability:50000 cycle
                                    • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 50 mm²
                                      Flexible with Ferrule 2x 2.5 ... 35 mm²
                                      Solid 1/2x 2.5 ... 16 mm²
                                      Stranded 1x 10 ... 70 mm²
                                      Stranded 2x 10 ... 50 mm²
                                    • Tightening Torque:Main Circuit 4 ... 6 N·m
                                    • Wire Stripping Length:Main Circuit 17 mm
                                    • Recommended Screw Driver:Hexagon 4
                                    • Mounting Position:Position 1 to 6
                                    • Actuator Type:Rotary Handle
                                    • Contact Position Indication:ON / OFF / TRIP
                                    • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
                                      TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
                                    • Standards:IEC/EN 60947-1
                                      IEC/EN 60947-2
                                      IEC/EN 60947-4-1
                                      UL 508
                                      CSA 22.2 No. 14
                                    Environmental
                                    • Ambient Air Temperature:Operation -20 ... +70 °C
                                      Operation Compensated -20 ... +60 °C
                                      Storage -50 ... +80 °C
                                    • Ambient Air Temperature Compensation:Yes
                                    • Maximum Operating Altitude Permissible:2000 m
                                    • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 25g
                                    • RoHS Status:Following EU Directive 2011/65/EC
                                      Request
                                      Callback


                                      Additional Information:

                                      • Pay Mode Terms: T/T (Bank Transfer)
                                      Send Business Enquiry

                                      ABB MO495 ( Manual Motor Starter/ Circuit Breakers)

                                      ABB MO495 ( Manual Motor Starter/ Circuit Breakers)
                                      • ABB MO495 ( Manual Motor Starter/ Circuit Breakers)
                                      Ask For Price
                                      Product Price :Get Latest Price

                                      Product Details:

                                      Minimum Order Quantity1 Number
                                      Poles Number3 Pole
                                      Power415V
                                      Rated current63-100Amps
                                      Rated short circuit breaking capacity50kA

                                      General Information
                                      • Extended Product Type:MO495
                                      • Catalog Description:MO495 Manual Motor Starter Magnetic Only
                                      • Long Description:The MO495 manual motor starter magnetic only is a 55 mm width device with a rated operational current of Ie = 63.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter magnetic only offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC. Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases and shunt trips are available as accessory.
                                      Dimensions
                                      • Product Net Width:70 mm
                                      • Product Net Height:165 mm
                                      • Product Net Depth:174 mm
                                      • Product Net Weight:2.244 kg
                                      Specification
                                      • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA
                                        (400 V AC) 25 kA
                                        (440 V AC) 20 kA
                                        (500 V AC) 6 kA
                                        (690 V AC) 3 kA
                                      • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
                                        (400 V AC) 50 kA
                                        (440 V AC) 50 kA
                                        (500 V AC) 12 kA
                                        (690 V AC) 6 kA
                                      • Rated Instantaneous Short-Circuit Current Setting (Ii):819 A
                                      • Setting Range:None
                                      • Rated Operational Voltage:Main Circuit 690 V AC
                                        Main Circuit 450 V DC
                                      • Rated Operational Current (Ie):63 A
                                      • Rated Operational Current AC-3 (Ie):63 A
                                      • Rated Frequency (f):Main Circuit 50 Hz
                                        Main Circuit 60 Hz
                                      • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
                                      • Rated Insulation Voltage (Ui):690 V
                                      • Power Loss:at Rated Operating Conditions per Pole 6.7 W
                                      • Number of Poles:3
                                      • Conventional Free-air Thermal Current (Ith):Main Circuit 63 A
                                      • Degree of Protection:Housing IP20
                                        Main Circuit Terminals IP00
                                      • Pollution Degree:3
                                      • Electrical Durability:25000 cycle
                                      • Mechanical Durability:50000 cycle
                                      • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 50 mm²
                                        Flexible with Ferrule 2x 2.5 ... 35 mm²
                                        Solid 1/2x 2.5 ... 16 mm²
                                        Stranded 1x 10 ... 70 mm²
                                        Stranded 2x 10 ... 50 mm²
                                      • Tightening Torque:Main Circuit 4 ... 6 N·m
                                      • Wire Stripping Length:Main Circuit 17 mm
                                      • Recommended Screw Driver:Hexagon 4
                                      • Mounting Position:Position 1 to 6
                                      • Actuator Type:Rotary Handle
                                      • Contact Position Indication:ON / OFF / TRIP
                                      • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
                                        TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
                                      • Standards:IEC/EN 60947-1
                                        IEC/EN 60947-2
                                        IEC/EN 60947-4-1
                                        UL 508
                                        CSA 22.2 No. 14
                                      • Remarks:For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
                                      Environmental
                                      • Ambient Air Temperature:Operation -20 ... +70 °C
                                        Storage -50 ... +80 °C
                                      • Ambient Air Temperature Compensation:No
                                      • Maximum Operating Altitude Permissible:2000 m
                                      • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 25g
                                      • RoHS Status:Following EU Directive 2011/65/EC
                                        Request
                                        Callback


                                        Additional Information:

                                        • Pay Mode Terms: T/T (Bank Transfer)
                                        Send Business Enquiry

                                        ABB MO496 ( Manual Motor Starter/ Circuit Breaker)

                                        ABB MO496 ( Manual Motor Starter/ Circuit Breaker)
                                        • ABB MO496 ( Manual Motor Starter/ Circuit Breaker)
                                        Ask For Price
                                        Product Price :Get Latest Price

                                        Product Details:

                                        Minimum Order Quantity1 Number
                                        Poles Number3 Pole
                                        Power415V
                                        Rated current32-100Amps
                                        Rated short circuit breaking capacity100kA

                                        General Information
                                        • Extended Product Type:MO496
                                        • Catalog Description:MO496 Manual Motor Starter Magnetic Only
                                        • Long Description:The MO496 manual motor starter magnetic only is a 55 mm width device with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits. The manual motor starter magnetic only offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC. Further features are the build-in disconnect function, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases and shunt trips are available as accessory.
                                        Dimensions
                                        • Product Net Width:70 mm
                                        • Product Net Height:165 mm
                                        • Product Net Depth:174 mm
                                        • Product Net Weight:2.208 kg
                                        Specification
                                        • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA
                                          (400 V AC) 50 kA
                                          (440 V AC) 50 kA
                                          (500 V AC) 11 kA
                                          (690 V AC) 7 kA
                                        • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
                                          (400 V AC) 100 kA
                                          (440 V AC) 100 kA
                                          (500 V AC) 22 kA
                                          (690 V AC) 12 kA
                                        • Rated Instantaneous Short-Circuit Current Setting (Ii):416 A
                                        • Setting Range:None
                                        • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 15 kW
                                        • Rated Operational Voltage:Main Circuit 690 V AC
                                          Main Circuit 450 V DC
                                        • Rated Operational Current (Ie):32 A
                                        • Rated Operational Current AC-3 (Ie):32 A
                                        • Rated Frequency (f):Main Circuit 50 Hz
                                          Main Circuit 60 Hz
                                        • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
                                        • Rated Insulation Voltage (Ui):690 V
                                        • Power Loss:at Rated Operating Conditions per Pole 6.7 W
                                        • Number of Poles:3
                                        • Conventional Free-air Thermal Current (Ith):Main Circuit 32 A
                                        • Degree of Protection:Housing IP20
                                          Main Circuit Terminals IP00
                                        • Pollution Degree:3
                                        • Electrical Durability:25000 cycle
                                        • Mechanical Durability:50000 cycle
                                        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 50 mm²
                                          Flexible with Ferrule 2x 2.5 ... 35 mm²
                                          Solid 1/2x 2.5 ... 16 mm²
                                          Stranded 1x 10 ... 70 mm²
                                          Stranded 2x 10 ... 50 mm²
                                        • Tightening Torque:Main Circuit 4 ... 6 N·m
                                        • Wire Stripping Length:Main Circuit 17 mm
                                        • Recommended Screw Driver:Hexagon 4
                                        • Mounting Position:Position 1 to 6
                                        • Actuator Type:Rotary Handle
                                        • Contact Position Indication:ON / OFF / TRIP
                                        • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
                                          TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
                                        • Standards:IEC/EN 60947-1
                                          IEC/EN 60947-2
                                          IEC/EN 60947-4-1
                                          UL 508
                                          CSA 22.2 No. 14
                                        • Remarks:For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
                                        Environmental
                                        • Ambient Air Temperature:Operation -20 ... +70 °C
                                          Storage -50 ... +80 °C
                                        • Ambient Air Temperature Compensation:No
                                        • Maximum Operating Altitude Permissible:2000 m
                                        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 25g
                                        • RoHS Status:Following EU Directive 2011/65/EC
                                          Request
                                          Callback


                                          Additional Information:

                                          • Pay Mode Terms: T/T (Bank Transfer)
                                          Send Business Enquiry

                                          ABB T4H PR221 DS-LS/I Circuit Breaker

                                          ABB T4H PR221 DS-LS/I Circuit Breaker
                                          • ABB T4H PR221 DS-LS/I Circuit Breaker
                                          Ask For Price
                                          Product Price :Get Latest Price

                                          Product Details:

                                          Minimum Order Quantity1 Unit
                                          BrandABB
                                          Voltage220V
                                          poles 3

                                          General Information
                                          • Extended Product Type:T4H 250 PR221DS-LS/I In=250 3p F F
                                          • Catalog Description:T4H 250 PR221DS-LS/I In=250 3p F F
                                          • Long Description:C.BREAKER TMAX T4H 250 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR221DS-LS/I R 250
                                          Dimensions
                                          • Product Net Width:105 mm
                                          • Product Net Height:205 mm
                                          • Product Net Depth:103.5 mm
                                          • Product Net Weight:3.5 kg
                                          Specification
                                          • Electrical Durability:8000 cycle
                                            120 cycles per hour
                                          • IIT Publishing Status:Level 0 - Information enabled
                                          • Mechanical Durability:20000 cycle
                                            240 cycles per hour
                                          • Number of Poles:3
                                          • Power Loss:at Rated Operating Conditions per Pole 10,7 W
                                          • Product Main Type:SACE Tmax T
                                          • Product Name:Moulded Case Circuit Breaker
                                          • Product Type:CB
                                          • Rated Current (In):250 A
                                          • Rated Impulse Withstand Voltage (Uimp):8 kV
                                          • Rated Insulation Voltage (Ui):1000 V
                                          • Rated Operational Voltage:690 V AC
                                            750 V DC
                                          • Rated Service Short-Circuit Breaking Capacity (Ics):(220 V AC) 150 kA
                                            (230 V AC) 150 kA
                                            (380 V AC) 70 kA
                                            (400 V AC) 70 kA
                                            (415 V AC) 70 kA
                                            (440 V AC) 65 kA
                                            (500 V AC) 50 kA
                                            (690 V AC) 40 kA
                                          • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(220 V AC) 10 kA
                                            (230 V AC) 10 kA
                                            (380 V AC) 70 kA
                                            (400 V AC) 70 kA
                                            (415 V AC) 70 kA
                                            (440 V AC) 65 kA
                                            (500 V AC) 50 kA
                                            (690 V AC) 40 kA
                                            (250 V DC) 2 Poles in Series 70 kA
                                            (500 V DC) 2 Poles in Series 50 kA
                                            (750 V DC) 3 Poles in Series 36 kA
                                          • Rated Uninterrupted Current (Iu):250 A
                                          • Release Type:EL
                                          • Standards:IEC 60947
                                          • Sub-type:T4
                                          • Suitable For:T4
                                          • Suitable for Product Class:Moulded Case Circuit Breakers
                                          • Terminal Connection Type:Fixed Circuit-Breakers
                                            Front
                                          • Test Voltage at Industrial Frequency for 1 Minute:3500 V
                                          • Test Voltage Max (Utest):3500 V
                                          • Version:F
                                            Request
                                            Callback


                                            Additional Information:

                                            • Pay Mode Terms: T/T (Bank Transfer)
                                            Send Business Enquiry
                                            X

                                            Explore more products



                                            Reach Us
                                            M.Siva Kumar (Sales Engineer)
                                            No. 63, 1st Floor Kaleeswara Mill Road, Ram Nagar
                                            Coimbatore- 641009, Tamil Nadu, India



                                            Call Us

                                            Share Us

                                            F GT L


                                            Send E-mailSend SMS