ABB Control Product

Leading Distributor / Channel Partner of e2.2 w fp iu 2000 3p hr hr for solar applications, abb hkf1-10 (auxiliary contact- front), abb sk1-20 ( signaling contacts- right), abb ck1-20( signaling contact- right), abb ta80du 80 (thermal overload relay) and abb ta80du 63 ( thermal overload relay) from Coimbatore.

E2.2 W FP Iu 2000 3p HR HR For Solar applications

₹ 20000/Piece Get Latest Price

Product Brochure
No.of PolesTriple Pole
BrandABB
Model Name/Number1SDA073909R1
Voltage900 V
Country of OriginMade in India

Minimum order quantity: 1 Piece

FIXED PART WITHDRAWABLE FOR C.BREAKER SACE EMAX2 E2.2 2000 THREE-POLE WITH REAR HORIZONTAL TERMINALS  - For Solar applications

ABB HKF1-10 (Auxiliary Contact- Front)

₹ 247/Unit Get Latest Price

Contactor TypeAuxiliary Contactors
Starter TypeSuitable for manual motor starter
PhaseThree Phase
BrandABB
Filter Tuned7th

General Information

  • Extended Product Type:HKF1-10
  • Product ID:1SAM201901R1003
  • Catalog Description:HKF1-10 Auxiliary Contact
  • Long Description:HKF1-10 Aux.-contact for front mounting
Dimensions
  • Product Net Width:45 mm
  • Product Net Height:12.5 mm
  • Product Net Depth:26.5 mm
  • Product Net Weight:0.013 kg
Specification
  • Rated Operational Voltage:250 V
  • Rated Operational Current AC-15 (Ie):(240 V) 4 A
    (24 V) 6 A
    (380 / 400 V) 3 A
    (690 V) 1 A
  • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
    (24 V) 2 A
    (250 V) 0.27 A
  • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
  • Rated Insulation Voltage (Ui):250 V
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
    Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
    Flexible 1/2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1.0 ... 2.5 mm²
  • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:Auxiliary Circuit 8 mm
  • Recommended Screw Driver:M3
    Pozidriv 2
  • Number of Auxiliary Contacts NO:1
  • Product Name:Auxiliary Contact
  • Suitable For:MS165
    MO165
    MS132
    MO132
    MS116
Environmental
  • Ambient Air Temperature:Operation -20 ... +55 °C
    Storage -50 ... +80 °C

    ABB SK1-20 ( Signaling Contacts- Right)

    ₹ 690/Unit Get Latest Price

    Power60 W
    Speed500 rpm
    PhaseThree Phase
    Starter Typesuitable for manual motor starter
    BrandABB

    Minimum order quantity: 1 Unit

    General Information

    • Extended Product Type:SK1-20
    • Product ID:1SAM201903R1002
    • Catalog Description:SK1-20 Signal Contact
    • Long Description:SK1-20 Signal contact
    Dimensions
    • Product Net Width:9 mm
    • Product Net Height:90 mm
    • Product Net Depth:78.5 mm
    • Product Net Weight:0.035 kg
    Specification
    • Rated Operational Voltage:690 V AC
      600 V DC
      Main Circuit 690 V
    • Rated Operational Current AC-15 (Ie):(240 V) 4 A
      (24 V) 6 A
      (380 / 400 V) 3 A
      (690 V) 1 A
    • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
      (24 V) 2 A
      (250 V) 0.27 A
      (440 V) 0 A
      (600 V) 0 A
    • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
    • Rated Insulation Voltage (Ui):690 V
    • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
      Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
      Flexible 1/2x 0.75 ... 1.5 mm²
      Rigid 1/2x 1 ... 1.5 mm²
    • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
    • Wire Stripping Length:Auxiliary Circuit 8 mm
    • Recommended Screw Driver:M3
      Pozidriv 2
    • Number of Auxiliary Contacts NO:2
    • Number of Auxiliary Contacts NC:0
    • Standards:IEC/EN 60947-1
      IEC/EN 60947-4-1
      IEC/EN 60947-5-1
      UL 60947-1
      UL 60947-4-1
    • Product Name:Signal Contact
    • Suitable For:MS116
      MS132
    • Suitable for Product Class:Manual Motor Starter
    Environmental
    • Ambient Air Temperature:Operation -20 ... +55 °C
      Storage -50 ... +80 °C
    • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

      ABB CK1-20( Signaling Contact- Right)

      ₹ 979/Unit Get Latest Price

      Starter Type Semi Automatic Star Delta Starter
      Coil Voltage 120 V
      Current Rating 30 A
      Phase Three Phase
      SUITABLE FORMS132

      Minimum order quantity: 1 Unit

      General Information

      • Extended Product Type:CK1-20
      • Product ID:1SAM301901R1002
      • Catalog Description:CK1-20 Short Circuit Signaling Contact
      • Long Description:CK1-20 Short-Circuit Signal Contact 1 NO+1 NC
      Dimensions
      • Product Net Width:9 mm
      • Product Net Height:90 mm
      • Product Net Depth:78 mm
      • Product Net Weight:0.035 kg
      Specification
      • Rated Operational Voltage:690 V AC
        600 V DC
        Main Circuit 690 V
      • Rated Operational Current AC-15 (Ie):(240 V) 4 A
        (24 V) 6 A
        (380 / 400 V) 3 A
        (690 V) 1 A
      • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
        (24 V) 2 A
        (250 V) 0.27 A
        (440 V) 0 A
        (600 V) 0 A
      • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
      • Rated Insulation Voltage (Ui):690 V
      • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
        Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
        Flexible 1/2x 0.75 ... 1.5 mm²
        Rigid 1/2x 1 ... 1.5 mm²
      • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
      • Wire Stripping Length:Auxiliary Circuit 8 mm
      • Recommended Screw Driver:M3
        Pozidriv 2
      • Number of Auxiliary Contacts NO:2
      • Number of Auxiliary Contacts NC:0
      • Standards:IEC/EN 60947-1
        IEC/EN 60947-2
        IEC/EN 60947-4-1
        IEC/EN 60947-5-1
        UL 508
        CSA 22.2 No. 14
      • Product Name:Short Circuit Signaling Contact
      • Suitable For:MS132
      • Suitable for Product Class:Manual Motor Starter
      Environmental
      • RoHS Status:Following EU Directive 2011/65/EC

        ABB TA80DU 80 (Thermal Overload Relay)

        ₹ 3197/Unit Get Latest Price

        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)60.0-80.0Amps
        Applicationprotect from phase loss and overload

        Minimum order quantity: 1 Unit

        General Information

        • Extended Product Type:TA80DU-80
        • Product ID:1SAZ331201R2006
        • Catalog Description:TA80DU-80 Thermal Overload Relay
        • Long Description:The TA80DU-80 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:78 mm
        • Product Net Height:97 mm
        • Product Net Depth:111 mm
        • Product Net Weight:0.375 kg
        Specification
        • Setting Range:60 ... 80 A
        • Rated Operational Voltage:Auxiliary Circuit 440 V DC
          Auxiliary Circuit 500 V AC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):80 A
        • Rated Operational Current AC-3 (Ie):80 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
          (120 V) NO 1.5 A
          (240 V) NC 3 A
          (240 V) NO 1.5 A
          (400 V) NC 1.9 A
          (400 V) NO 1 A
          (440 V) NC 1 A
          (440 V) NO 1 A
          (500 V) NC 1 A
          (500 V) NO 1 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
          (125 V) NO 0.25 A
          (24 V) NC 1.25 A
          (24 V) NO 1.25 A
          (250 V) NC 0.12 A
          (250 V) NO 0.04 A
          (60 V) NC 0.25 A
          (60 V) NO 0.25 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
          Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
          Flexible with Ferrule 2x 2.5 ... 10 mm²
          Rigid 1x 2.5 ... 25 mm²
          Rigid 2x 2.5 ... 16 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 4.5 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 14 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 2.2 ... 3.9 W
        • Suitable For:A95
          A110
          AE95
          AE110
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 60947-1
          UL 60947-4-1
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C
        • Ambient Air Temperature Compensation:Yes
        • Maximum Operating Altitude Permissible:2000 m
        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
        • RoHS Status:Following EU Directive 2011/65/EC

        ABB TA80DU 63 ( Thermal Overload Relay)

        ₹ 2978/Unit Get Latest Price

        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)45.0-63.0Amps
        Applicationprotect from phase loss and overload

        Minimum order quantity: 1 Unit

        General Information

        • Extended Product Type:TA80DU-63
        • Product ID:1SAZ331201R2005
        • Catalog Description:TA80DU-63 Thermal Overload Relay
        • Long Description:The TA80DU-63 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:78 mm
        • Product Net Height:97 mm
        • Product Net Depth:111 mm
        • Product Net Weight:0.365 kg
        Specification
        • Setting Range:45 ... 63 A
        • Rated Operational Voltage:Auxiliary Circuit 440 V DC
          Auxiliary Circuit 500 V AC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):63 A
        • Rated Operational Current AC-3 (Ie):63 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
          (120 V) NO 1.5 A
          (240 V) NC 3 A
          (240 V) NO 1.5 A
          (400 V) NC 1.9 A
          (400 V) NO 1 A
          (440 V) NC 1 A
          (440 V) NO 1 A
          (500 V) NC 1 A
          (500 V) NO 1 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
          (125 V) NO 0.25 A
          (24 V) NC 1.25 A
          (24 V) NO 1.25 A
          (250 V) NC 0.12 A
          (250 V) NO 0.04 A
          (60 V) NC 0.25 A
          (60 V) NO 0.25 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
          Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
          Flexible with Ferrule 2x 2.5 ... 10 mm²
          Rigid 1x 2.5 ... 25 mm²
          Rigid 2x 2.5 ... 16 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 4.5 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 14 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 1.9 ... 3.8 W
        • Suitable For:A95
          A110
          AE95
          AE110
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 60947-1
          UL 60947-4-1
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C
        • Ambient Air Temperature Compensation:Yes
        • Maximum Operating Altitude Permissible:2000 m
        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
        • RoHS Status:Following EU Directive 2011/65/EC

        ABB TA80DU-52 ( Thermal Overload Relay)

        ₹ 2978/Unit Get Latest Price

        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)36.0-52.0Amps
        ApplicationProtect from phase loss and overload

        Minimum order quantity: 1 Unit

        General Information

        • Extended Product Type:TA80DU-52
        • Product ID:1SAZ331201R2004
        • Catalog Description:TA80DU-52 Thermal Overload Relay
        • Long Description:The TA80DU-52 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:78 mm
        • Product Net Height:97 mm
        • Product Net Depth:111 mm
        • Product Net Weight:0.365 kg
        Specification
        • Setting Range:36 ... 52 A
        • Rated Operational Voltage:Auxiliary Circuit 440 V DC
          Auxiliary Circuit 500 V AC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):52 A
        • Rated Operational Current AC-3 (Ie):52 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3 A
          (120 V) NO 1.5 A
          (240 V) NC 3 A
          (240 V) NO 1.5 A
          (400 V) NC 1.9 A
          (400 V) NO 1 A
          (440 V) NC 1 A
          (440 V) NO 1 A
          (500 V) NC 1 A
          (500 V) NO 1 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.25 A
          (125 V) NO 0.25 A
          (24 V) NC 1.25 A
          (24 V) NO 1.25 A
          (250 V) NC 0.12 A
          (250 V) NO 0.04 A
          (60 V) NC 0.25 A
          (60 V) NO 0.25 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
          Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
          Flexible with Ferrule 2x 2.5 ... 10 mm²
          Rigid 1x 2.5 ... 25 mm²
          Rigid 2x 2.5 ... 16 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 4.5 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 14 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 1.7 ... 3.5 W
        • Suitable For:A95
          A110
          AE95
          AE110
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 60947-1
          UL 60947-4-1
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C
        • Ambient Air Temperature Compensation:Yes
        • Maximum Operating Altitude Permissible:2000 m
        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
        • RoHS Status:Following EU Directive 2011/65/EC
        .

        ABB TA25DU 25M ( Thermal Overload Relay)

        ₹ 1098/Unit Get Latest Price

        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)18.0-25.0Amps
        Applicationprotect from phase loss and overload

        Minimum order quantity: 1 Unit

        General Information

        • Extended Product Type:TA25DU-25M
        • Product ID:1SAZ211201R2051
        • Catalog Description:TA25DU-25M Thermal Overload Relays
        • Long Description:TA25DU-25M (18.0-25A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:44 mm
        • Product Net Height:80 mm
        • Product Net Depth:94 mm
        • Product Net Weight:0.17 kg
        Specification
        • Setting Range:18.0 ... 25.0 A
        • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):25 A
        • Rated Operational Current AC-3 (Ie):25 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
          (120 V) NO 1.500 A
          (240 V) NC 3.000 A
          (240 V) NO 1.500 A
          (400 V) NC 1.900 A
          (400 V) NO 1.000 A
          (440 V) NC 1.000 A
          (440 V) NO 1.000 A
          (500 V) NC 1.000 A
          (500 V) NO 1.000 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
          (125 V) NO 0.250 A
          (24 V) NC 1.250 A
          (24 V) NO 1.250 A
          (250 V) NC 0.120 A
          (250 V) NO 0.040 A
          (60 V) NC 0.250 A
          (60 V) NO 0.250 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
          Flexible with Ferrule 2x 0.75 ... 4 mm²
          Flexible 1x 0.75 ... 4 mm²
          Flexible 2x 0.75 ... 4 mm²
          Rigid 1x 0.75 ... 4 mm²
          Rigid 2x 0.75 ... 4 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 1.5 ... 1.9 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 12 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 2.9 W
        • Suitable For:AX09
          AX12
          AX18
          AX25
          AX32
          AX40
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 508
          CSA 22.2 No. 14
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C
        • Ambient Air Temperature Compensation:Yes
        • Maximum Operating Altitude Permissible:2000 m
        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
        • RoHS Status:Following EU Directive 2011/65/EC

        ABB TA25DU 2.4M ( Thermal Overload Relay)

        ₹ 887/Unit Get Latest Price

        Voltage (V)415V
        Voltage TypeAC
        Number of Poles3 Pole
        Current (Amps)1.7-2.4Amps
        Applicationprotect from phase loss and overload

        Minimum order quantity: 1 Unit

        General Information

        • Extended Product Type:TA25DU-2.4M
        • Product ID:1SAZ211201R2028
        • Catalog Description:TA25DU-2.4M Thermal Overload Relays
        • Long Description:TA25DU-2.4M (1.7-2.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
        Dimensions
        • Product Net Width:44 mm
        • Product Net Height:80 mm
        • Product Net Depth:94 mm
        • Product Net Weight:0.15 kg
        Specification
        • Setting Range:1.70 ... 2.40 A
        • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
          Main Circuit 690 V AC
        • Rated Operational Current (Ie):2.4 A
        • Rated Operational Current AC-3 (Ie):2.4 A
        • Rated Frequency (f):Auxiliary Circuit 50 Hz
          Auxiliary Circuit 60 Hz
          Auxiliary Circuit DC
          Main Circuit 60 Hz
          Main Circuit 50 Hz
          Main Circuit DC
        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
          Main Circuit 6 kV
        • Rated Insulation Voltage (Ui):690 V
        • Number of Poles:3
        • Number of Auxiliary Contacts NC:1
        • Number of Auxiliary Contacts NO:1
        • Number of Protected Poles:3
        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
          Auxiliary Circuit NO 5 A
        • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
          (120 V) NO 1.500 A
          (240 V) NC 3.000 A
          (240 V) NO 1.500 A
          (400 V) NC 1.900 A
          (400 V) NO 1.000 A
          (440 V) NC 1.000 A
          (440 V) NO 1.000 A
          (500 V) NC 1.000 A
          (500 V) NO 1.000 A
        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
          (125 V) NO 0.250 A
          (24 V) NC 1.250 A
          (24 V) NO 1.250 A
          (250 V) NC 0.120 A
          (250 V) NO 0.040 A
          (60 V) NC 0.250 A
          (60 V) NO 0.250 A
        • Degree of Protection:Housing IP20
          Main Circuit Terminals IP10
        • Pollution Degree:3
        • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
          Rigid 1/2x 0.75 ... 4 mm²
        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
          Flexible with Ferrule 2x 0.75 ... 4 mm²
          Flexible 1x 0.75 ... 4 mm²
          Flexible 2x 0.75 ... 4 mm²
          Rigid 1x 0.75 ... 4 mm²
          Rigid 2x 0.75 ... 4 mm²
        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
          Main Circuit 1.5 ... 1.9 N·m
        • Wire Stripping Length:Auxiliary Circuit 9 mm
          Main Circuit 12 mm
        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
          Main Circuit Pozidriv 2
        • Mounting Position:Position 1 to 4
        • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
        • Suitable For:AX09
          AX12
          AX18
          AX25
          AX32
          AX40
        • Standards:IEC/EN 60947-1
          IEC/EN 60947-4-1
          IEC/EN 60947-5-1
          UL 508
          CSA 22.2 No. 14
        Environmental
        • Ambient Air Temperature:Operation -25 ... +55 °C
          Operation Compensated -25 ... +55 °C
          Storage -40 ... +70 °C

          ABB TA25DU 3.1M( Thermal Overload Relay)

          ₹ 887/Unit Get Latest Price

          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)2.2-3.1Amps
          Applicationprotect from overload and phase loss

          Minimum order quantity: 1 Unit

          General Information

          • Extended Product Type:TA25DU-3.1M
          • Product ID:1SAZ211201R2031
          • Catalog Description:TA25DU-3.1M Thermal Overload Relays
          • Long Description:TA25DU-3.1M (2.2-3.1A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:2.20 ... 3.10 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):3.1 A
          • Rated Operational Current AC-3 (Ie):3.1 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC

          ABB TA25DU 1.4M ( Thermal Overload Relay)

          ₹ 887/Unit Get Latest Price

          Voltage (V)415V
          Voltage TypeAC
          Number of Poles3 Pole
          Current (Amps)1.0-1.4Amps
          Applicationprotect from overload and phase loss

          Minimum order quantity: 1 Unit

          General Information

          • Extended Product Type:TA25DU-1.4M
          • Product ID:1SAZ211201R2023
          • Catalog Description:TA25DU-1.4M Thermal Overload Relays
          • Long Description:TA25DU-1.4M (1.0-1.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
          Dimensions
          • Product Net Width:44 mm
          • Product Net Height:80 mm
          • Product Net Depth:94 mm
          • Product Net Weight:0.15 kg
          Specification
          • Setting Range:1.00 ... 1.40 A
          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
            Main Circuit 690 V AC
          • Rated Operational Current (Ie):1.4 A
          • Rated Operational Current AC-3 (Ie):1.4 A
          • Rated Frequency (f):Auxiliary Circuit 50 Hz
            Auxiliary Circuit 60 Hz
            Auxiliary Circuit DC
            Main Circuit 60 Hz
            Main Circuit 50 Hz
            Main Circuit DC
          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
            Main Circuit 6 kV
          • Rated Insulation Voltage (Ui):690 V
          • Number of Poles:3
          • Number of Auxiliary Contacts NC:1
          • Number of Auxiliary Contacts NO:1
          • Number of Protected Poles:3
          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
            Auxiliary Circuit NO 5 A
          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
            (120 V) NO 1.500 A
            (240 V) NC 3.000 A
            (240 V) NO 1.500 A
            (400 V) NC 1.900 A
            (400 V) NO 1.000 A
            (440 V) NC 1.000 A
            (440 V) NO 1.000 A
            (500 V) NC 1.000 A
            (500 V) NO 1.000 A
          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
            (125 V) NO 0.250 A
            (24 V) NC 1.250 A
            (24 V) NO 1.250 A
            (250 V) NC 0.120 A
            (250 V) NO 0.040 A
            (60 V) NC 0.250 A
            (60 V) NO 0.250 A
          • Degree of Protection:Housing IP20
            Main Circuit Terminals IP10
          • Pollution Degree:3
          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
            Rigid 1/2x 0.75 ... 4 mm²
          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
            Flexible with Ferrule 2x 0.75 ... 4 mm²
            Flexible 1x 0.75 ... 4 mm²
            Flexible 2x 0.75 ... 4 mm²
            Rigid 1x 0.75 ... 4 mm²
            Rigid 2x 0.75 ... 4 mm²
          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
            Main Circuit 1.5 ... 1.9 N·m
          • Wire Stripping Length:Auxiliary Circuit 9 mm
            Main Circuit 12 mm
          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
            Main Circuit Pozidriv 2
          • Mounting Position:Position 1 to 4
          • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
          • Suitable For:AX09
            AX12
            AX18
            AX25
            AX32
            AX40
          • Standards:IEC/EN 60947-1
            IEC/EN 60947-4-1
            IEC/EN 60947-5-1
            UL 508
            CSA 22.2 No. 14
          Environmental
          • Ambient Air Temperature:Operation -25 ... +55 °C
            Operation Compensated -25 ... +55 °C
            Storage -40 ... +70 °C
          • Ambient Air Temperature Compensation:Yes
          • Maximum Operating Altitude Permissible:2000 m
          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
          • RoHS Status:Following EU Directive 2011/65/EC

            ABB TA25DU 1.8M ( Thermal Overload Relay)

            ₹ 887/Unit Get Latest Price

            Voltage (V)415v
            Voltage TypeAC
            Number of Poles3 Pole
            Current (Amps)1.3-1.8Amps
            Applicationprotect from overload and phase loss

            Minimum order quantity: 1 Unit

            General Information

            • Extended Product Type:TA25DU-1.8M
            • Product ID:1SAZ211201R2025
            • Catalog Description:TA25DU-1.8M Thermal Overload Relays
            • Long Description:TA25DU-1.8M (1.3-1.8A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
            Dimensions
            • Product Net Width:44 mm
            • Product Net Height:80 mm
            • Product Net Depth:94 mm
            • Product Net Weight:0.15 kg
            Specification
            • Setting Range:1.30 ... 1.80 A
            • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
              Main Circuit 690 V AC
            • Rated Operational Current (Ie):1.8 A
            • Rated Operational Current AC-3 (Ie):1.8 A
            • Rated Frequency (f):Auxiliary Circuit 50 Hz
              Auxiliary Circuit 60 Hz
              Auxiliary Circuit DC
              Main Circuit 60 Hz
              Main Circuit 50 Hz
              Main Circuit DC
            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
              Main Circuit 6 kV
            • Rated Insulation Voltage (Ui):690 V
            • Number of Poles:3
            • Number of Auxiliary Contacts NC:1
            • Number of Auxiliary Contacts NO:1
            • Number of Protected Poles:3
            • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
              Auxiliary Circuit NO 5 A
            • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
              (120 V) NO 1.500 A
              (240 V) NC 3.000 A
              (240 V) NO 1.500 A
              (400 V) NC 1.900 A
              (400 V) NO 1.000 A
              (440 V) NC 1.000 A
              (440 V) NO 1.000 A
              (500 V) NC 1.000 A
              (500 V) NO 1.000 A
            • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
              (125 V) NO 0.250 A
              (24 V) NC 1.250 A
              (24 V) NO 1.250 A
              (250 V) NC 0.120 A
              (250 V) NO 0.040 A
              (60 V) NC 0.250 A
              (60 V) NO 0.250 A
            • Degree of Protection:Housing IP20
              Main Circuit Terminals IP10
            • Pollution Degree:3
            • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
              Rigid 1/2x 0.75 ... 4 mm²
            • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
              Flexible with Ferrule 2x 0.75 ... 4 mm²
              Flexible 1x 0.75 ... 4 mm²
              Flexible 2x 0.75 ... 4 mm²
              Rigid 1x 0.75 ... 4 mm²
              Rigid 2x 0.75 ... 4 mm²
            • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
              Main Circuit 1.5 ... 1.9 N·m
            • Wire Stripping Length:Auxiliary Circuit 9 mm
              Main Circuit 12 mm
            • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
              Main Circuit Pozidriv 2
            • Mounting Position:Position 1 to 4
            • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
            • Suitable For:AX09
              AX12
              AX18
              AX25
              AX32
              AX40
            • Standards:IEC/EN 60947-1
              IEC/EN 60947-4-1
              IEC/EN 60947-5-1
              UL 508
              CSA 22.2 No. 14
            Environmental
            • Ambient Air Temperature:Operation -25 ... +55 °C
              Operation Compensated -25 ... +55 °C
              Storage -40 ... +70 °C
            • Ambient Air Temperature Compensation:Yes
            • Maximum Operating Altitude Permissible:2000 m
            • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
            • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA75DU 52M ( Thermal Overload Relay)

              ₹ 2703/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)36.0-52.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA75DU-52M
              • Product ID:1SAZ321201R2004
              • Catalog Description:TA75DU-52M Thermal Overload Relays
              • Long Description:TA75DU-52M (36.0-52.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.335 kg
              Specification
              • Setting Range:36.0 ... 52.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):52 A
              • Rated Operational Current AC-3 (Ie):52 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.7 ... 3.5 W
              • Suitable For:AX50
                AX65
                AX80
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA42DU 42( Thermal Overload Relay)

              ₹ 2014/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)29.0-42.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA42DU-42M
              • Product ID:1SAZ311201R2003
              • Catalog Description:TA42DU-42M Thermal Overload Relays
              • Long Description:TA42DU-42M (29.0-42.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.335 kg
              Specification
              • Setting Range:29.0 ... 42.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):42 A
              • Rated Operational Current AC-3 (Ie):42 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 3.2 W
              • Suitable For:AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA75DU 32M ( Thermal Overload Relay)

              ₹ 2302/Unit Get Latest Price

              Voltage (V)440v
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)22.0-32.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA75DU-32M
              • Product ID:1SAZ321201R2002
              • Catalog Description:TA75DU-32M Thermal Overload Relays
              • Long Description:TA75DU-32M (22.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.335 kg
              Specification
              • Setting Range:22.0 ... 32.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):32 A
              • Rated Operational Current AC-3 (Ie):32 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.4 ... 3.0 W
              • Suitable For:AX50
                AX65
                AX80
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA42DU 25( Thermal Overload Relay)

              ₹ 1824/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)18.0-25.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA42DU-25M
              • Product ID:1SAZ311201R2001
              • Catalog Description:TA42DU-25M Thermal Overload Relays
              • Long Description:TA42DU-25M (18.0-25.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.335 kg
              Specification
              • Setting Range:18.0 ... 25.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):25 A
              • Rated Operational Current AC-3 (Ie):25 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.8 ... 3.4 W
              • Suitable For:AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA42DU 32 ( Thermal Overload Relay)

              ₹ 1993/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)22.0-32.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA42DU-32M
              • Product ID:1SAZ311201R2002
              • Catalog Description:TA42DU-32M Thermal Overload Relays
              • Long Description:TA42DU-32M (22.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.335 kg
              Specification
              • Setting Range:22.0 ... 32.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):32 A
              • Rated Operational Current AC-3 (Ie):32 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.4 ... 3.0 W
              • Suitable For:AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 32M(Thermal Overload Relay)

              ₹ 1535/Unit Get Latest Price

              Voltage (V)415v
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)24.0-32.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-32M
              • Product ID:1SAZ211201R2053
              • Catalog Description:TA25DU-32M Thermal Overload Relays
              • Long Description:TA25DU-32M (24.0-32.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.2 kg
              Specification
              • Setting Range:24.0 ... 32.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):32 A
              • Rated Operational Current AC-3 (Ie):32 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 2.5 ... 3.2 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 15 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.8 ... 3.3 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 14M( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)10.0-14.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-14M
              • Product ID:1SAZ211201R2045
              • Catalog Description:TA25DU-14M Thermal Overload Relays
              • Long Description:TA25DU-14M (10.0-14.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:10.0 ... 14.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):14 A
              • Rated Operational Current AC-3 (Ie):14 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.2 ... 2.4 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 8.5M( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)6.0-8.5Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-8.5M
              • Product ID:1SAZ211201R2040
              • Catalog Description:TA25DU-8.5M Thermal Overload Relays
              • Long Description:TA25DU-8.5M (6.0-8.5A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:6.00 ... 8.50 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):8.5 A
              • Rated Operational Current AC-3 (Ie):8.5 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 11M ( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)7.50-11.0Amps
              Applicationprotect from overload and phase loss

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-11M
              • Product ID:1SAZ211201R2043
              • Catalog Description:TA25DU-11M Thermal Overload Relays
              • Long Description:TA25DU-11M (7.5-11A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:7.50 ... 11.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):11 A
              • Rated Operational Current AC-3 (Ie):11 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 5.0M ( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)3.5-5.0Amps
              Applicationprotect from overload and phase loss

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-5.0M
              • Product ID:1SAZ211201R2035
              • Catalog Description:TA25DU-5.0M Thermal Overload Relays
              • Long Description:TA25DU-5.0M (3.5-5.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:3.50 ... 5.00 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):5 A
              • Rated Operational Current AC-3 (Ie):5 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 6.5M( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415v
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)4.5-6.5Amps
              Applicationprotect from overload and phase loss

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-6.5M
              • Product ID:1SAZ211201R2038
              • Catalog Description:TA25DU-6.5M Thermal Overload Relays
              • Long Description:TA25DU-6.5M (4.5-6.5A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:4.50 ... 6.50 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):6.5 A
              • Rated Operational Current AC-3 (Ie):6.5 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA75DU 80M( Thermal Overload Relay)

              ₹ 2901/Unit Get Latest Price

              Voltage (V)415V
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)60.0-80.0Amps
              Applicationprotect from phase loss and overload

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA75DU-80M
              • Product ID:1SAZ321201R2006
              • Catalog Description:TA75DU-80M Thermal Overload Relays
              • Long Description:TA75DU-80M (60.0-80.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:54 mm
              • Product Net Height:90 mm
              • Product Net Depth:111 mm
              • Product Net Weight:0.37 kg
              Specification
              • Setting Range:60.0 ... 80.0 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):80 A
              • Rated Operational Current AC-3 (Ie):80 A
              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                Main Circuit DC/50/60 Hz
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP20
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Flexible with Ferrule 2x 2.5 ... 10 mm²
                Rigid 1x 2.5 ... 25 mm²
                Rigid 2x 2.5 ... 16 mm²
              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                Main Circuit AuxiliaryCircuit4.5 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 14 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 2.5 ... 4.4 W
              • Suitable For:AX50
                AX65
                AX80
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB TA25DU 4.0M( Thermal Overload Relay)

              ₹ 887/Unit Get Latest Price

              Voltage (V)415v
              Voltage TypeAC
              Number of Poles3 Pole
              Current (Amps)2.8-4.0Amps
              Applicationprotect from overload and phase loss

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:TA25DU-4.0M
              • Product ID:1SAZ211201R2033
              • Catalog Description:TA25DU-4.0M Thermal Overload Relays
              • Long Description:TA25DU-4.0M (2.8-4.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
              Dimensions
              • Product Net Width:44 mm
              • Product Net Height:80 mm
              • Product Net Depth:94 mm
              • Product Net Weight:0.15 kg
              Specification
              • Setting Range:2.80 ... 4.00 A
              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                Main Circuit 690 V AC
              • Rated Operational Current (Ie):4 A
              • Rated Operational Current AC-3 (Ie):4 A
              • Rated Frequency (f):Auxiliary Circuit 50 Hz
                Auxiliary Circuit 60 Hz
                Auxiliary Circuit DC
                Main Circuit 60 Hz
                Main Circuit 50 Hz
                Main Circuit DC
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                Main Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Number of Poles:3
              • Number of Auxiliary Contacts NC:1
              • Number of Auxiliary Contacts NO:1
              • Number of Protected Poles:3
              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                Auxiliary Circuit NO 5 A
              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                (120 V) NO 1.500 A
                (240 V) NC 3.000 A
                (240 V) NO 1.500 A
                (400 V) NC 1.900 A
                (400 V) NO 1.000 A
                (440 V) NC 1.000 A
                (440 V) NO 1.000 A
                (500 V) NC 1.000 A
                (500 V) NO 1.000 A
              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                (125 V) NO 0.250 A
                (24 V) NC 1.250 A
                (24 V) NO 1.250 A
                (250 V) NC 0.120 A
                (250 V) NO 0.040 A
                (60 V) NC 0.250 A
                (60 V) NO 0.250 A
              • Degree of Protection:Housing IP20
                Main Circuit Terminals IP10
              • Pollution Degree:3
              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                Rigid 1/2x 0.75 ... 4 mm²
              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                Flexible with Ferrule 2x 0.75 ... 4 mm²
                Flexible 1x 0.75 ... 4 mm²
                Flexible 2x 0.75 ... 4 mm²
                Rigid 1x 0.75 ... 4 mm²
                Rigid 2x 0.75 ... 4 mm²
              • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                Main Circuit 1.5 ... 1.9 N·m
              • Wire Stripping Length:Auxiliary Circuit 9 mm
                Main Circuit 12 mm
              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                Main Circuit Pozidriv 2
              • Mounting Position:Position 1 to 4
              • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.2 W
              • Suitable For:AX09
                AX12
                AX18
                AX25
                AX32
                AX40
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              Environmental
              • Ambient Air Temperature:Operation -25 ... +55 °C
                Operation Compensated -25 ... +55 °C
                Storage -40 ... +70 °C
              • Ambient Air Temperature Compensation:Yes
              • Maximum Operating Altitude Permissible:2000 m
              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
              • RoHS Status:Following EU Directive 2011/65/EC

              ABB CK1-02( Signaling Contacts Right)

              ₹ 979/Unit Get Latest Price

              Contactor TypeAC Power Contactors
              PhaseThree Phase
              Starter Typemanual motor starter
              Coil Voltage480 V
              Filter Tuned5th

              Minimum order quantity: 1 Unit

              General Information

              • Extended Product Type:CK1-02
              • Product ID:1SAM301901R1003
              • Catalog Description:CK1-02 Short Circuit Signaling Contact
              • Long Description:CK1-02 Short-Circuit Signal Contact 2 NC
              Dimensions
              • Product Net Width:9 mm
              • Product Net Height:90 mm
              • Product Net Depth:78 mm
              • Product Net Weight:0.035 kg
              Specification
              • Rated Operational Voltage:690 V AC
                600 V DC
                Main Circuit 690 V
              • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                (24 V) 6 A
                (380 / 400 V) 3 A
                (690 V) 1 A
              • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                (24 V) 2 A
                (250 V) 0.27 A
                (440 V) 0 A
                (600 V) 0 A
              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
              • Rated Insulation Voltage (Ui):690 V
              • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                Flexible 1/2x 0.75 ... 1.5 mm²
                Rigid 1/2x 1 ... 1.5 mm²
              • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
              • Wire Stripping Length:Auxiliary Circuit 8 mm
              • Recommended Screw Driver:M3
                Pozidriv 2
              • Number of Auxiliary Contacts NO:0
              • Number of Auxiliary Contacts NC:2
              • Standards:IEC/EN 60947-1
                IEC/EN 60947-2
                IEC/EN 60947-4-1
                IEC/EN 60947-5-1
                UL 508
                CSA 22.2 No. 14
              • Product Name:Short Circuit Signaling Contact
              • Suitable For:MS132
              • Suitable for Product Class:Manual Motor Starter
              Environmental
              • RoHS Status:Following EU Directive 2011/65/EC

                ABB TA25DU 0.16M (Thermal Overload Relays)

                ₹ 887/Unit Get Latest Price

                Current Rating1.6A
                Voltage (V)415v
                Voltage TypeAC
                Current (Amps)0.1-0.16Amps
                ApplicationDirect mounting on contactors

                Minimum order quantity: 1 Unit

                General Information

                • Extended Product Type:TA25DU-0.16M
                • Product ID:1SAZ211201R2005
                • Catalog Description:TA25DU-0.16M Thermal Overload Relays
                • Long Description:TA25DU-0.16M (0.1-0.16A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                Dimensions
                • Product Net Width:44 mm
                • Product Net Height:80 mm
                • Product Net Depth:94 mm
                • Product Net Weight:0.15 kg
                Specification
                • Setting Range:0.10 ... 0.16 A
                • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                  Main Circuit 690 V AC
                • Rated Operational Current (Ie):0.16 A
                • Rated Operational Current AC-3 (Ie):0.16 A
                • Rated Frequency (f):Auxiliary Circuit 50 Hz
                  Auxiliary Circuit 60 Hz
                  Auxiliary Circuit DC
                  Main Circuit 60 Hz
                  Main Circuit 50 Hz
                  Main Circuit DC
                • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                  Main Circuit 6 kV
                • Rated Insulation Voltage (Ui):690 V
                • Number of Poles:3
                • Number of Auxiliary Contacts NC:1
                • Number of Auxiliary Contacts NO:1
                • Number of Protected Poles:3
                • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                  Auxiliary Circuit NO 5 A
                • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                  (120 V) NO 1.500 A
                  (240 V) NC 3.000 A
                  (240 V) NO 1.500 A
                  (400 V) NC 1.900 A
                  (400 V) NO 1.000 A
                  (440 V) NC 1.000 A
                  (440 V) NO 1.000 A
                  (500 V) NC 1.000 A
                  (500 V) NO 1.000 A
                • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                  (125 V) NO 0.250 A
                  (24 V) NC 1.250 A
                  (24 V) NO 1.250 A
                  (250 V) NC 0.120 A
                  (250 V) NO 0.040 A
                  (60 V) NC 0.250 A
                  (60 V) NO 0.250 A
                • Degree of Protection:Housing IP20
                  Main Circuit Terminals IP10
                • Pollution Degree:3
                • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                  Rigid 1/2x 0.75 ... 4 mm²
                • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                  Flexible with Ferrule 2x 0.75 ... 4 mm²
                  Flexible 1x 0.75 ... 4 mm²
                  Flexible 2x 0.75 ... 4 mm²
                  Rigid 1x 0.75 ... 4 mm²
                  Rigid 2x 0.75 ... 4 mm²
                • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                  Main Circuit 1.5 ... 1.9 N·m
                • Wire Stripping Length:Auxiliary Circuit 9 mm
                  Main Circuit 12 mm
                • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                  Main Circuit Pozidriv 2
                • Mounting Position:Position 1 to 4
                • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                • Suitable For:AX09
                  AX12
                  AX18
                  AX25
                  AX32
                  AX40
                • Standards:IEC/EN 60947-1
                  IEC/EN 60947-4-1
                  IEC/EN 60947-5-1
                  UL 508
                  CSA 22.2 No. 14
                Environmental
                • Ambient Air Temperature:Operation -25 ... +55 °C
                  Operation Compensated -25 ... +55 °C
                  Storage -40 ... +70 °C
                • Ambient Air Temperature Compensation:Yes
                • Maximum Operating Altitude Permissible:2000 m
                • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                • RoHS Status:Following EU Directive 2011/65/EC

                  ABB HKF1-01 (Auxiliary Contact-front)

                  ₹ 247/Unit Get Latest Price

                  Starter Type Semi Automatic Star Delta Starter
                  Coil Voltage 120 V
                  Current Rating 40 A
                  Suitable for:manual motor starter

                  Minimum order quantity: 1 Unit

                  General Information

                  • Extended Product Type:HKF1-01
                  • Product ID:1SAM201901R1004
                  • Catalog Description:HKF1-01 Auxiliary Contact
                  • Long Description:HKF1-01 Aux.-contact for front mounting
                  Dimensions
                  • Product Net Width:45 mm
                  • Product Net Height:12.5 mm
                  • Product Net Depth:26.5 mm
                  • Product Net Weight:0.013 kg
                  Specification
                  • Rated Operational Voltage:250 V
                  • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                    (24 V) 6 A
                    (380 / 400 V) 3 A
                    (690 V) 1 A
                  • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                    (24 V) 2 A
                    (250 V) 0.27 A
                  • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                  • Rated Insulation Voltage (Ui):250 V
                  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                    Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                    Flexible 1/2x 0.75 ... 1.5 mm²
                    Rigid 1/2x 1.0 ... 2.5 mm²
                  • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                  • Wire Stripping Length:Auxiliary Circuit 8 mm
                  • Recommended Screw Driver:M3
                    Pozidriv 2
                  • Number of Auxiliary Contacts NC:1
                  • Product Name:Auxiliary Contact
                  • Suitable For:MS165
                    MO165
                    MS132
                    MO132
                    MS116
                  Environmental
                  • Ambient Air Temperature:Operation -20 ... +55 °C
                    Storage -50 ... +80 °C

                    ABB SK1-02 ( Signaling Contacts- Right)

                    ₹ 690/Unit Get Latest Price

                    BrandABB
                    Starter TypeSUITABLE FOR MANUAL MOTOR STARTER
                    Phase Three Phase
                    Suitable for Manual motor starter

                    Minimum order quantity: 1 Unit

                    General Information

                    • Extended Product Type:SK1-02
                    • Product ID:1SAM201903R1003
                    • Catalog Description:SK1-02 Signal Contact
                    • Long Description:SK1-02 Signal contact
                    Dimensions
                    • Product Net Width:9 mm
                    • Product Net Height:90 mm
                    • Product Net Depth:78.5 mm
                    • Product Net Weight:0.035 kg
                    Specification
                    • Rated Operational Voltage:690 V AC
                      600 V DC
                      Main Circuit 690 V
                    • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                      (24 V) 6 A
                      (380 / 400 V) 3 A
                      (690 V) 1 A
                    • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                      (24 V) 2 A
                      (250 V) 0.27 A
                      (440 V) 0 A
                      (600 V) 0 A
                    • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                    • Rated Insulation Voltage (Ui):690 V
                    • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                      Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                      Flexible 1/2x 0.75 ... 1.5 mm²
                      Rigid 1/2x 1 ... 1.5 mm²
                    • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                    • Wire Stripping Length:Auxiliary Circuit 8 mm
                    • Recommended Screw Driver:M3
                      Pozidriv 2
                    • Number of Auxiliary Contacts NO:0
                    • Number of Auxiliary Contacts NC:2
                    • Standards:IEC/EN 60947-1
                      IEC/EN 60947-4-1
                      IEC/EN 60947-5-1
                      UL 60947-1
                      UL 60947-4-1
                    • Product Name:Signal Contact
                    • Suitable For:MS116
                      MS132
                    • Suitable for Product Class:Manual Motor Starter
                    Environmental
                    • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

                      ABB TA25DU 0.63M( Thermal Overload Relay)

                      ₹ 887/Unit Get Latest Price

                      Voltage (V)415v
                      Voltage TypeAC
                      Current (Amps)0.4-0.63Amps
                      Applicationdirect mounting on contactors

                      Minimum order quantity: 1 Unit

                      General Information

                      • Extended Product Type:TA25DU-0.63M
                      • Product ID:1SAZ211201R2017
                      • Catalog Description:TA25DU-0.63M Thermal Overload Relays
                      • Long Description:TA25DU-0.63M (0.4-0.63A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                      Dimensions
                      • Product Net Width:44 mm
                      • Product Net Height:80 mm
                      • Product Net Depth:94 mm
                      • Product Net Weight:0.15 kg
                      Specification
                      • Setting Range:0.40 ... 0.63 A
                      • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                        Main Circuit 690 V AC
                      • Rated Operational Current (Ie):0.63 A
                      • Rated Operational Current AC-3 (Ie):0.63 A
                      • Rated Frequency (f):Auxiliary Circuit 50 Hz
                        Auxiliary Circuit 60 Hz
                        Auxiliary Circuit DC
                        Main Circuit 60 Hz
                        Main Circuit 50 Hz
                        Main Circuit DC
                      • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                        Main Circuit 6 kV
                      • Rated Insulation Voltage (Ui):690 V
                      • Number of Poles:3
                      • Number of Auxiliary Contacts NC:1
                      • Number of Auxiliary Contacts NO:1
                      • Number of Protected Poles:3
                      • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                        Auxiliary Circuit NO 5 A
                      • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                        (120 V) NO 1.500 A
                        (240 V) NC 3.000 A
                        (240 V) NO 1.500 A
                        (400 V) NC 1.900 A
                        (400 V) NO 1.000 A
                        (440 V) NC 1.000 A
                        (440 V) NO 1.000 A
                        (500 V) NC 1.000 A
                        (500 V) NO 1.000 A
                      • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                        (125 V) NO 0.250 A
                        (24 V) NC 1.250 A
                        (24 V) NO 1.250 A
                        (250 V) NC 0.120 A
                        (250 V) NO 0.040 A
                        (60 V) NC 0.250 A
                        (60 V) NO 0.250 A
                      • Degree of Protection:Housing IP20
                        Main Circuit Terminals IP10
                      • Pollution Degree:3
                      • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                        Rigid 1/2x 0.75 ... 4 mm²
                      • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                        Flexible with Ferrule 2x 0.75 ... 4 mm²
                        Flexible 1x 0.75 ... 4 mm²
                        Flexible 2x 0.75 ... 4 mm²
                        Rigid 1x 0.75 ... 4 mm²
                        Rigid 2x 0.75 ... 4 mm²
                      • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                        Main Circuit 1.5 ... 1.9 N·m
                      • Wire Stripping Length:Auxiliary Circuit 9 mm
                        Main Circuit 12 mm
                      • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                        Main Circuit Pozidriv 2
                      • Mounting Position:Position 1 to 4
                      • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                      • Suitable For:AX09
                        AX12
                        AX18
                        AX25
                        AX32
                        AX40
                      • Standards:IEC/EN 60947-1
                        IEC/EN 60947-4-1
                        IEC/EN 60947-5-1
                        UL 508
                        CSA 22.2 No. 14
                      Environmental
                      • Ambient Air Temperature:Operation -25 ... +55 °C
                        Operation Compensated -25 ... +55 °C
                        Storage -40 ... +70 °C
                      • Ambient Air Temperature Compensation:Yes
                      • Maximum Operating Altitude Permissible:2000 m
                      • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                      • RoHS Status:Following EU Directive 2011/65/EC

                        ABB TA25DU 1.0M (Thermal Overload Relay)

                        ₹ 887/Unit Get Latest Price

                        Voltage (V)415V
                        Voltage TypeAC
                        Current (Amps)0.63-1.0Amps
                        ApplicationDirect mounting on contactors

                        Minimum order quantity: 1 Unit

                        General Information

                        • Extended Product Type:TA25DU-1.0M
                        • Product ID:1SAZ211201R2021
                        • Catalog Description:TA25DU-1.0M Thermal Overload Relays
                        • Long Description:TA25DU-1.0M (0.63-1.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                        Dimensions
                        • Product Net Width:44 mm
                        • Product Net Height:80 mm
                        • Product Net Depth:94 mm
                        • Product Net Weight:0.15 kg
                        Specification
                        • Setting Range:0.63 ... 1.00 A
                        • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                          Main Circuit 690 V AC
                        • Rated Operational Current (Ie):1 A
                        • Rated Operational Current AC-3 (Ie):1 A
                        • Rated Frequency (f):Auxiliary Circuit 50 Hz
                          Auxiliary Circuit 60 Hz
                          Auxiliary Circuit DC
                          Main Circuit 60 Hz
                          Main Circuit 50 Hz
                          Main Circuit DC
                        • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                          Main Circuit 6 kV
                        • Rated Insulation Voltage (Ui):690 V
                        • Number of Poles:3
                        • Number of Auxiliary Contacts NC:1
                        • Number of Auxiliary Contacts NO:1
                        • Number of Protected Poles:3
                        • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                          Auxiliary Circuit NO 5 A
                        • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                          (120 V) NO 1.500 A
                          (240 V) NC 3.000 A
                          (240 V) NO 1.500 A
                          (400 V) NC 1.900 A
                          (400 V) NO 1.000 A
                          (440 V) NC 1.000 A
                          (440 V) NO 1.000 A
                          (500 V) NC 1.000 A
                          (500 V) NO 1.000 A
                        • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                          (125 V) NO 0.250 A
                          (24 V) NC 1.250 A
                          (24 V) NO 1.250 A
                          (250 V) NC 0.120 A
                          (250 V) NO 0.040 A
                          (60 V) NC 0.250 A
                          (60 V) NO 0.250 A
                        • Degree of Protection:Housing IP20
                          Main Circuit Terminals IP10
                        • Pollution Degree:3
                        • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                          Rigid 1/2x 0.75 ... 4 mm²
                        • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                          Flexible with Ferrule 2x 0.75 ... 4 mm²
                          Flexible 1x 0.75 ... 4 mm²
                          Flexible 2x 0.75 ... 4 mm²
                          Rigid 1x 0.75 ... 4 mm²
                          Rigid 2x 0.75 ... 4 mm²
                        • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                          Main Circuit 1.5 ... 1.9 N·m
                        • Wire Stripping Length:Auxiliary Circuit 9 mm
                          Main Circuit 12 mm
                        • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                          Main Circuit Pozidriv 2
                        • Mounting Position:Position 1 to 4
                        • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                        • Suitable For:AX09
                          AX12
                          AX18
                          AX25
                          AX32
                          AX40
                        • Standards:IEC/EN 60947-1
                          IEC/EN 60947-4-1
                          IEC/EN 60947-5-1
                          UL 508
                          CSA 22.2 No. 14
                        Environmental
                        • Ambient Air Temperature:Operation -25 ... +55 °C
                          Operation Compensated -25 ... +55 °C
                          Storage -40 ... +70 °C
                        • Ambient Air Temperature Compensation:Yes
                        • Maximum Operating Altitude Permissible:2000 m
                        • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                        • RoHS Status:Following EU Directive 2011/65/EC

                          ABB TA25DU 0.25M (Thermal Overload Relay)

                          ₹ 887/Unit Get Latest Price

                          Voltage (V)415V
                          Voltage TypeAC
                          Current (Amps)0.16-0.25Amps
                          Applicationdirect mounting on contactors

                          Minimum order quantity: 1 Unit

                          General Information

                          • Extended Product Type:TA25DU-0.25M
                          • Product ID:1SAZ211201R2009
                          • Catalog Description:TA25DU-0.25M Thermal Overload Relays
                          • Long Description:TA25DU-0.25M (0.16-0.25A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                          Dimensions
                          • Product Net Width:44 mm
                          • Product Net Height:80 mm
                          • Product Net Depth:94 mm
                          • Product Net Weight:0.15 kg
                          Technical
                          • Setting Range:0.16 ... 0.25 A
                          • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                            Main Circuit 690 V AC
                          • Rated Operational Current (Ie):0.25 A
                          • Rated Operational Current AC-3 (Ie):0.25 A
                          • Rated Frequency (f):Auxiliary Circuit 50 Hz
                            Auxiliary Circuit 60 Hz
                            Auxiliary Circuit DC
                            Main Circuit 60 Hz
                            Main Circuit 50 Hz
                            Main Circuit DC
                          • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                            Main Circuit 6 kV
                          • Rated Insulation Voltage (Ui):690 V
                          • Number of Poles:3
                          • Number of Auxiliary Contacts NC:1
                          • Number of Auxiliary Contacts NO:1
                          • Number of Protected Poles:3
                          • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                            Auxiliary Circuit NO 5 A
                          • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                            (120 V) NO 1.500 A
                            (240 V) NC 3.000 A
                            (240 V) NO 1.500 A
                            (400 V) NC 1.900 A
                            (400 V) NO 1.000 A
                            (440 V) NC 1.000 A
                            (440 V) NO 1.000 A
                            (500 V) NC 1.000 A
                            (500 V) NO 1.000 A
                          • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                            (125 V) NO 0.250 A
                            (24 V) NC 1.250 A
                            (24 V) NO 1.250 A
                            (250 V) NC 0.120 A
                            (250 V) NO 0.040 A
                            (60 V) NC 0.250 A
                            (60 V) NO 0.250 A
                          • Degree of Protection:Housing IP20
                            Main Circuit Terminals IP10
                          • Pollution Degree:3
                          • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                            Rigid 1/2x 0.75 ... 4 mm²
                          • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                            Flexible with Ferrule 2x 0.75 ... 4 mm²
                            Flexible 1x 0.75 ... 4 mm²
                            Flexible 2x 0.75 ... 4 mm²
                            Rigid 1x 0.75 ... 4 mm²
                            Rigid 2x 0.75 ... 4 mm²
                          • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                            Main Circuit 1.5 ... 1.9 N·m
                          • Wire Stripping Length:Auxiliary Circuit 9 mm
                            Main Circuit 12 mm
                          • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                            Main Circuit Pozidriv 2
                          • Mounting Position:Position 1 to 4
                          • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                          • Suitable For:AX09
                            AX12
                            AX18
                            AX25
                            AX32
                            AX40
                          • Standards:IEC/EN 60947-1
                            IEC/EN 60947-4-1
                            IEC/EN 60947-5-1
                            UL 508
                            CSA 22.2 No. 14
                          Environmental
                          • Ambient Air Temperature:Operation -25 ... +55 °C
                            Operation Compensated -25 ... +55 °C
                            Storage -40 ... +70 °C
                          • Ambient Air Temperature Compensation:Yes
                          • Maximum Operating Altitude Permissible:2000 m
                          • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                          • RoHS Status:Following EU Directive 2011/65/EC

                            ABB TA25DU 19M( Thermal Overload Relay)

                            ₹ 1098/Unit Get Latest Price

                            Voltage (V)415V
                            Voltage TypeAC
                            Current (Amps)13.0-19.0Amps
                            ApplicationProtect from Phase Loss and Overload

                            Minimum order quantity: 1 Unit

                            General Information

                            • Extended Product Type:TA25DU-19M
                            • Product ID:1SAZ211201R2047
                            • Catalog Description:TA25DU-19M Thermal Overload Relays
                            • Long Description:TA25DU-19M (13.0-19.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                            Dimensions
                            • Product Net Width:44 mm
                            • Product Net Height:80 mm
                            • Product Net Depth:94 mm
                            • Product Net Weight:0.17 kg
                            Specification
                            • Setting Range:13.0 ... 19.0 A
                            • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                              Main Circuit 690 V AC
                            • Rated Operational Current (Ie):19 A
                            • Rated Operational Current AC-3 (Ie):19 A
                            • Rated Frequency (f):Auxiliary Circuit 50 Hz
                              Auxiliary Circuit 60 Hz
                              Auxiliary Circuit DC
                              Main Circuit 60 Hz
                              Main Circuit 50 Hz
                              Main Circuit DC
                            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                              Main Circuit 6 kV
                            • Rated Insulation Voltage (Ui):690 V
                            • Number of Poles:3
                            • Number of Auxiliary Contacts NC:1
                            • Number of Auxiliary Contacts NO:1
                            • Number of Protected Poles:3
                            • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                              Auxiliary Circuit NO 5 A
                            • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                              (120 V) NO 1.500 A
                              (240 V) NC 3.000 A
                              (240 V) NO 1.500 A
                              (400 V) NC 1.900 A
                              (400 V) NO 1.000 A
                              (440 V) NC 1.000 A
                              (440 V) NO 1.000 A
                              (500 V) NC 1.000 A
                              (500 V) NO 1.000 A
                            • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                              (125 V) NO 0.250 A
                              (24 V) NC 1.250 A
                              (24 V) NO 1.250 A
                              (250 V) NC 0.120 A
                              (250 V) NO 0.040 A
                              (60 V) NC 0.250 A
                              (60 V) NO 0.250 A
                            • Degree of Protection:Housing IP20
                              Main Circuit Terminals IP10
                            • Pollution Degree:3
                            • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                              Rigid 1/2x 0.75 ... 4 mm²
                            • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                              Flexible with Ferrule 2x 0.75 ... 4 mm²
                              Flexible 1x 0.75 ... 4 mm²
                              Flexible 2x 0.75 ... 4 mm²
                              Rigid 1x 0.75 ... 4 mm²
                              Rigid 2x 0.75 ... 4 mm²
                            • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                              Main Circuit 1.5 ... 1.9 N·m
                            • Wire Stripping Length:Auxiliary Circuit 9 mm
                              Main Circuit 12 mm
                            • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                              Main Circuit Pozidriv 2
                            • Mounting Position:Position 1 to 4
                            • Power Loss:at Rated Operating Conditions per Pole 1.1 ... 2.3 W
                            • Suitable For:AX09
                              AX12
                              AX18
                              AX25
                              AX32
                              AX40
                            • Standards:IEC/EN 60947-1
                              IEC/EN 60947-4-1
                              IEC/EN 60947-5-1
                              UL 508
                              CSA 22.2 No. 14
                            Environmental
                            • Ambient Air Temperature:Operation -25 ... +55 °C
                              Operation Compensated -25 ... +55 °C
                              Storage -40 ... +70 °C
                            • Ambient Air Temperature Compensation:Yes
                            • Maximum Operating Altitude Permissible:2000 m
                            • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                            • RoHS Status:Following EU Directive 2011/65/EC

                            ABB TA25DU 0.4M (Thermal Overload Relay)

                            ₹ 887/Unit Get Latest Price

                            Voltage (V)415V
                            Voltage TypeAC
                            Current (Amps)0.25-0.4Amps
                            ApplicationDirect mounting on contactors

                            Minimum order quantity: 1 Unit

                            General Information

                            • Extended Product Type:TA25DU-0.4M
                            • Product ID:1SAZ211201R2013
                            • Catalog Description:TA25DU-0.4M Thermal Overload Relays
                            • Long Description:TA25DU-0.4M (0.25-0.4A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                            Dimensions
                            • Product Net Width:44 mm
                            • Product Net Height:80 mm
                            • Product Net Depth:94 mm
                            • Product Net Weight:0.15 kg
                            Specification
                            • Setting Range:0.25 ... 0.40 A
                            • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                              Main Circuit 690 V AC
                            • Rated Operational Current (Ie):0.4 A
                            • Rated Operational Current AC-3 (Ie):0.4 A
                            • Rated Frequency (f):Auxiliary Circuit 50 Hz
                              Auxiliary Circuit 60 Hz
                              Auxiliary Circuit DC
                              Main Circuit 60 Hz
                              Main Circuit 50 Hz
                              Main Circuit DC
                            • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                              Main Circuit 6 kV
                            • Rated Insulation Voltage (Ui):690 V
                            • Number of Poles:3
                            • Number of Auxiliary Contacts NC:1
                            • Number of Auxiliary Contacts NO:1
                            • Number of Protected Poles:3
                            • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                              Auxiliary Circuit NO 5 A
                            • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                              (120 V) NO 1.500 A
                              (240 V) NC 3.000 A
                              (240 V) NO 1.500 A
                              (400 V) NC 1.900 A
                              (400 V) NO 1.000 A
                              (440 V) NC 1.000 A
                              (440 V) NO 1.000 A
                              (500 V) NC 1.000 A
                              (500 V) NO 1.000 A
                            • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                              (125 V) NO 0.250 A
                              (24 V) NC 1.250 A
                              (24 V) NO 1.250 A
                              (250 V) NC 0.120 A
                              (250 V) NO 0.040 A
                              (60 V) NC 0.250 A
                              (60 V) NO 0.250 A
                            • Degree of Protection:Housing IP20
                              Main Circuit Terminals IP10
                            • Pollution Degree:3
                            • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                              Rigid 1/2x 0.75 ... 4 mm²
                            • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 0.75 ... 4 mm²
                              Flexible with Ferrule 2x 0.75 ... 4 mm²
                              Flexible 1x 0.75 ... 4 mm²
                              Flexible 2x 0.75 ... 4 mm²
                              Rigid 1x 0.75 ... 4 mm²
                              Rigid 2x 0.75 ... 4 mm²
                            • Tightening Torque:Auxiliary Circuit 1 ... 1.3 N·m
                              Main Circuit 1.5 ... 1.9 N·m
                            • Wire Stripping Length:Auxiliary Circuit 9 mm
                              Main Circuit 12 mm
                            • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                              Main Circuit Pozidriv 2
                            • Mounting Position:Position 1 to 4
                            • Power Loss:at Rated Operating Conditions per Pole 0.9 ... 2.2 W
                            • Suitable For:AX09
                              AX12
                              AX18
                              AX25
                              AX32
                              AX40
                            • Standards:IEC/EN 60947-1
                              IEC/EN 60947-4-1
                              IEC/EN 60947-5-1
                              UL 508
                              CSA 22.2 No. 14
                            Environmental
                            • Ambient Air Temperature:Operation -25 ... +55 °C
                              Operation Compensated -25 ... +55 °C
                              Storage -40 ... +70 °C
                            • Ambient Air Temperature Compensation:Yes
                            • Maximum Operating Altitude Permissible:2000 m
                            • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                            • RoHS Status:Following EU Directive 2011/65/EC

                              T4V-HA 250 TMA 250-2500 3p F F 800V

                              ₹ 24669/Piece Get Latest Price

                              BrandABB
                              No. of PolesTriple Pole
                              Rated Current250A
                              Breaking Capacity25kA
                              Voltage800V
                              Country of OriginMade in India

                              T4V-HA 250 TMA 250-2500 3p F F 800V AC

                              T4V-HA 250 TMA 100-1000 3p F F 800V AC

                              ₹ 22425/Piece Get Latest Price

                              BrandABB
                              No. of PolesTriple Pole
                              Rated Current100A
                              Breaking Capacity25kA
                              Voltage800V
                              Model Name/Number1SDA083659R1
                              Country of OriginMade in India

                              T4V-HA 250 TMA 100-1000 3p F F 800V AC

                              ABB TA25DU 1M 0.63 TO 1

                              ₹ 2040/Piece Get Latest Price

                              Current Rating2.8A
                              Rated Voltage690 volt
                              No. of PolesTriple Pole
                              FrequencyAuxiliary Circuit 50 hertz/Auxiliary Circuit 60 hertz/Auxiliary Circuit DC, Main Circuit 60 hertz/M
                              Country of OriginMade in India

                              TA25DU-1.0M Thermal overload relay Trip class 10A, 0.63-1.0A

                              ABB TA75DU 63M ( Thermal Overload Relay)

                              ₹ 2703/Unit Get Latest Price

                              Voltage (V)415V
                              Voltage TypeAC
                              Number of Poles3 Pole
                              Current (Amps)45.0-63.0Amps
                              Applicationprotect from phase loss and overload

                              Minimum order quantity: 1 Unit

                              General Information

                              • Extended Product Type:TA75DU-63M
                              • Product ID:1SAZ321201R2005
                              • Catalog Description:TA75DU-63M Thermal Overload Relays
                              • Long Description:TA75DU-63M (45.0-63.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                              Dimensions
                              • Product Net Width:54 mm
                              • Product Net Height:90 mm
                              • Product Net Depth:111 mm
                              • Product Net Weight:0.335 kg
                              Specification
                              • Setting Range:45.0 ... 63.0 A
                              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                                Main Circuit 690 V AC
                              • Rated Operational Current (Ie):63 A
                              • Rated Operational Current AC-3 (Ie):63 A
                              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                                Main Circuit DC/50/60 Hz
                              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                                Main Circuit 6 kV
                              • Rated Insulation Voltage (Ui):690 V
                              • Number of Poles:3
                              • Number of Auxiliary Contacts NC:1
                              • Number of Auxiliary Contacts NO:1
                              • Number of Protected Poles:3
                              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                                Auxiliary Circuit NO 5 A
                              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                                (120 V) NO 1.500 A
                                (240 V) NC 3.000 A
                                (240 V) NO 1.500 A
                                (400 V) NC 1.900 A
                                (400 V) NO 1.000 A
                                (440 V) NC 1.000 A
                                (440 V) NO 1.000 A
                                (500 V) NC 1.000 A
                                (500 V) NO 1.000 A
                              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                                (125 V) NO 0.250 A
                                (24 V) NC 1.250 A
                                (24 V) NO 1.250 A
                                (250 V) NC 0.120 A
                                (250 V) NO 0.040 A
                                (60 V) NC 0.250 A
                                (60 V) NO 0.250 A
                              • Degree of Protection:Housing IP20
                                Main Circuit Terminals IP20
                              • Pollution Degree:3
                              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                                Rigid 1/2x 0.75 ... 4 mm²
                              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                                Flexible with Ferrule 2x 2.5 ... 10 mm²
                                Flexible with Ferrule 2x 2.5 ... 10 mm²
                                Rigid 1x 2.5 ... 25 mm²
                                Rigid 2x 2.5 ... 16 mm²
                              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                                Main Circuit AuxiliaryCircuit4.5 N·m
                              • Wire Stripping Length:Auxiliary Circuit 9 mm
                                Main Circuit 14 mm
                              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                                Main Circuit Pozidriv 2
                              • Mounting Position:Position 1 to 4
                              • Power Loss:at Rated Operating Conditions per Pole 1.9 ... 3.8 W
                              • Suitable For:AX50
                                AX65
                                AX80
                              • Standards:IEC/EN 60947-1
                                IEC/EN 60947-4-1
                                IEC/EN 60947-5-1
                                UL 508
                                CSA 22.2 No. 14
                              Environmental
                              • Ambient Air Temperature:Operation -25 ... +55 °C
                                Operation Compensated -25 ... +55 °C
                                Storage -40 ... +70 °C
                              • Ambient Air Temperature Compensation:Yes
                              • Maximum Operating Altitude Permissible:2000 m
                              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                              • RoHS Status:Following EU Directive 2011/65/EC

                              ABB TA75DU 42M ( Thermal Overload Relay)

                              ₹ 2703/Unit Get Latest Price

                              Voltage (V)415V
                              Voltage TypeAC
                              Number of Poles3 Pole
                              Current (Amps)29.0-42.0Amps
                              Applicationprotect from phase loss and overload

                              Minimum order quantity: 1 Unit

                              General Information

                              • Extended Product Type:TA75DU-42M
                              • Product ID:1SAZ321201R2003
                              • Catalog Description:TA75DU-42M Thermal Overload Relays
                              • Long Description:TA75DU-42M (29.0-42.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
                              Dimensions
                              • Product Net Width:54 mm
                              • Product Net Height:90 mm
                              • Product Net Depth:111 mm
                              • Product Net Weight:0.335 kg
                              Specification
                              • Setting Range:29.0 ... 42.0 A
                              • Rated Operational Voltage:Auxiliary Circuit 440/500 V AC/DC
                                Main Circuit 690 V AC
                              • Rated Operational Current (Ie):42 A
                              • Rated Operational Current AC-3 (Ie):42 A
                              • Rated Frequency (f):Auxiliary Circuit DC/50/60 Hz
                                Main Circuit DC/50/60 Hz
                              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                                Main Circuit 6 kV
                              • Rated Insulation Voltage (Ui):690 V
                              • Number of Poles:3
                              • Number of Auxiliary Contacts NC:1
                              • Number of Auxiliary Contacts NO:1
                              • Number of Protected Poles:3
                              • Conventional Free-air Thermal Current (Ith):Auxiliary Circuit NC 5 A
                                Auxiliary Circuit NO 5 A
                              • Rated Operational Current AC-15 (Ie):(120 V) NC 3.000 A
                                (120 V) NO 1.500 A
                                (240 V) NC 3.000 A
                                (240 V) NO 1.500 A
                                (400 V) NC 1.900 A
                                (400 V) NO 1.000 A
                                (440 V) NC 1.000 A
                                (440 V) NO 1.000 A
                                (500 V) NC 1.000 A
                                (500 V) NO 1.000 A
                              • Rated Operational Current DC-13 (Ie):(125 V) NC 0.250 A
                                (125 V) NO 0.250 A
                                (24 V) NC 1.250 A
                                (24 V) NO 1.250 A
                                (250 V) NC 0.120 A
                                (250 V) NO 0.040 A
                                (60 V) NC 0.250 A
                                (60 V) NO 0.250 A
                              • Degree of Protection:Housing IP20
                                Main Circuit Terminals IP20
                              • Pollution Degree:3
                              • Connecting Capacity Auxiliary Circuit:Flexible 1/2x 0.75 ... 2.5 mm²
                                Rigid 1/2x 0.75 ... 4 mm²
                              • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 2.5 ... 25 mm²
                                Flexible with Ferrule 2x 2.5 ... 10 mm²
                                Flexible with Ferrule 2x 2.5 ... 10 mm²
                                Rigid 1x 2.5 ... 25 mm²
                                Rigid 2x 2.5 ... 16 mm²
                              • Tightening Torque:Main Circuit 1 ... 1.3 N·m
                                Main Circuit AuxiliaryCircuit4.5 N·m
                              • Wire Stripping Length:Auxiliary Circuit 9 mm
                                Main Circuit 14 mm
                              • Recommended Screw Driver:Auxiliary Circuit Pozidriv 1
                                Main Circuit Pozidriv 2
                              • Mounting Position:Position 1 to 4
                              • Power Loss:at Rated Operating Conditions per Pole 1.5 ... 3.2 W
                              • Suitable For:AX50
                                AX65
                                AX80
                              • Standards:IEC/EN 60947-1
                                IEC/EN 60947-4-1
                                IEC/EN 60947-5-1
                                UL 508
                                CSA 22.2 No. 14
                              Environmental
                              • Ambient Air Temperature:Operation -25 ... +55 °C
                                Operation Compensated -25 ... +55 °C
                                Storage -40 ... +70 °C
                              • Ambient Air Temperature Compensation:Yes
                              • Maximum Operating Altitude Permissible:2000 m
                              • Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 12g
                              • RoHS Status:Following EU Directive 2011/65/EC

                              ABB HK1-20 ( Auxiliary Contacts- Right)

                              Get Latest Price

                              Power18.5 KW
                              PhaseThree Phase
                              Starter Typesuitable for manual motor
                              BrandABB
                              Country of OriginMade in India

                              General Information

                              • Extended Product Type:HK1-20
                              • Product ID:1SAM201902R1002
                              • Catalog Description:HK1-20 Auxiliary Contact
                              • Long Description:HK1-20 Aux.-contact
                              Dimensions
                              • Product Net Width:9 mm
                              • Product Net Height:90 mm
                              • Product Net Depth:78.5 mm
                              • Product Net Weight:0.035 kg
                              Specification
                              • Rated Operational Voltage:690 V AC
                                600 V DC
                                Main Circuit 690 V
                              • Rated Operational Current AC-15 (Ie):(240 V) 4 A
                                (24 V) 6 A
                                (380 / 400 V) 3 A
                                (690 V) 1 A
                              • Rated Operational Current DC-13 (Ie):(125 V) 0.55 A
                                (24 V) 2 A
                                (250 V) 0.27 A
                                (440 V) 0 A
                                (600 V) 0 A
                              • Rated Impulse Withstand Voltage (Uimp):Auxiliary Circuit 6 kV
                              • Rated Insulation Voltage (Ui):690 V
                              • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 1.5 mm²
                                Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm²
                                Flexible 1/2x 0.75 ... 1.5 mm²
                                Rigid 1/2x 1 ... 1.5 mm²
                              • Tightening Torque:Auxiliary Circuit 0.8 ... 1.2 N·m
                              • Wire Stripping Length:Auxiliary Circuit 8 mm
                              • Recommended Screw Driver:M3
                                Pozidriv 2
                              • Number of Auxiliary Contacts NO:2
                              • Number of Auxiliary Contacts NC:0
                              • Standards:IEC/EN 60947-1
                                IEC/EN 60947-4-1
                                IEC/EN 60947-5-1
                                UL 60947-1
                                UL 60947-4-1
                              • Product Name:Auxiliary Contact
                              • Suitable For:MS116
                                MS132
                              • Suitable for Product Class:Manual Motor Starter
                              Environmental
                              • Ambient Air Temperature:Operation -20 ... +55 °C
                                Storage -50 ... +80 °C
                              • RoHS Status:Following EU Directive 2002/95/EC August 18, 2005 and amendment

                                X

                                Contact Us

                                Sales Coordinator (Sales Coordinator)
                                Pigeon Agency
                                No. 63, 1st Floor Kaleeswara Mill Road, Ram Nagar
                                Somasundra, Coimbatore - 641009, Tamil Nadu, India

                                Get Directions
                                Send Email
                                Share:
                                Thank youYour Enquiry has been sent successfully.